Laserfiche WebLink
BUILDING PERMIT <br />DATE/TIME 07/06/98 15:50 <br />TYPE Resident. addition/alteration <br />OCCUPANCY R-2 <br />CONST TYPE V-N <br />UGB: SITE: FD <br /> <br /> PERMIT NO <br /> STATUS <br /> ISSUED <br /> TO EXPIRE <br /> PAGE <br /> No. 6 through 18 bar = 2 inches <br /> No. 5 bar, W31 or D31 wire and smaller = 1 1/2 inches. <br />C. Concrete not exposed to weather or in contact with <br /> ground: Slabs, walls, joists. No. 11 bar and smaller = <br /> <br /> 3/4 inches. <br />10. AI'FIC ACCESS, A readily accessible attic access shall be <br /> provided to any attic area having a clear height gf over <br /> 20 inches, A framed opening not less than 22 incnes by <br /> 30 inches is required. [Sec, 807.1] <br />11. EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue. <br /> The window sill height shall not be more than 44 inches <br /> above the floor, The minimum net clear opening is 5,7 square <br /> feet. The minimum net clear opening height shall be 22 <br /> inches, The minimum net clear opening width shall be 20 <br /> inches. Exception: Grade floor windows may have a minimum <br /> net clear opening of 5 square feet. [Sec. 210,2. 210.2,1] <br />12. STAIRWAYS shall not be less than 36 qnches in clear width at <br /> all points between the handrail height and the required <br /> minimum headroom of 6 feet 8 inches. Minimum width from the <br /> handrail down is 32 inches with one handrail. 28 inches with <br /> two. The minimum required stair tread width is 9 inches, <br /> The maximum stair rise is 8 inches. When r~sers are closed, <br /> all treads less than 10 inches shall have a uniform nosing <br /> betweem 3/4 inches and I 1/4 ~nches. The greatest riser <br /> height/tread depth shall not exced th smallest by more than <br /> 3lB inch. [Sec. 314,1; 314.2; 214.2.1; 314.3] <br />12. HANDRAILS having a m~nimum and maximum height of 30 inches <br /> and 38 inches, respectively, shall be provided on at least <br /> one s~de of stairways of more than three risers. All re- <br /> quired handrails shall be continuous the full length of the <br /> stairs, The handgrip portion of the handrails shall not be <br /> less than 1-1/4" or more than 2-5/8" in cross sectional <br /> dimension, or the shape shall provide an equivalent gripping <br /> surface, The handgrip portion of handrails shall have ,, <br /> smooth surface and edges shall have a minimum radius of 1/8 <br />14: GUARDRAILS. Porches or raised floor surfaces located more <br /> than 20 inches above the finished grade shall have guard- <br /> rails not less than 36 inches in height. The required guard <br /> rail shall have intermediate rails or ornamental closures <br /> which do not allow passage of an object 4 inches or more in <br /> diameter. Horizontal spacing between the vertical members <br /> in required gurardrails shall be a maximum of 4" at the <br /> nearest point between the members, <br /> [Sec. 315.3; 315.4] <br />15. ALL INTERIOR STAIRS shall be provided with a minimum of 60 <br /> watts of incandescent light or other artificial light source <br /> rated at a minimum of 850 lumens, Interior stairs of six <br /> steps or more shall have the required lighting located in <br /> the immediate vicinity of the top and bottom of the stairs, <br /> and the required lighting shall be controlled from the top <br /> and bottom of stairs provided the artificial light source is <br /> located directly over each stair section, [Section 303.4] <br />16. SMOKE DETECTORS located outside sleeping rooms shall be <br /> interconnected such that the actuation of one alram will <br /> actuate these alarms in the individual unit and shall <br /> ~rovide an alarm which will be audible in all sleeping areas <br /> moke detectors shall be 110 volt with battery back-up, <br /> Sec. 216.1 <br />17. FIRESTOPPING shall be provided in the following locations. <br /> 1. In concealed spaces of stud walls, including furred <br /> spaces not to exceed 10 feet horizontally, and at the <br /> ceiling and floor level, <br /> 2. At all interconnections between concealed vertical and h <br /> horizontal spaces such as occur at soffits, drop or cove <br /> ceilings, etc, <br /> 3. In concealed spaces between stair stringers at the top <br /> and bottom of the run and wall cavities in line with the <br /> stringers: <br /> 4, At openings around vents, pipes, ducts, chimneys, fire- <br /> places at ceilings/floor level, w/non-combustible materials. <br />18. HEATING APPLIANCES shall be accessible for inspection. <br /> <br />98-04901 <br />ISSUED <br />07/06/1998 <br />01/02/1999 <br /> 3 <br /> <br /> <br />