My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12989299
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
15-XXXXXX
>
12989299
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 8:00:14 PM
Creation date
7/31/2025 4:12:09 PM
Metadata
Fields
Template:
Permits
Permit Address
6792 SCISM RD NE
Permit City
Silverton
Permit Number
555-15-000086-DWL
Parcel Number
061W30B 01600
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRE AND SMOKE PROTECTION FEATURES <br /> 1.2. By a horizontal distance of not less than 712.1 shall be protected in accordance with Sections 714.4.1 <br /> the depth of the wall cavity where the through 714.4.2.2. <br /> ` wall cavity is filled with cellulose loose- 714.4.1 Fire-resistance-rated assemblies.Penetrations of <br /> fill,rockwool or slag mineral wool insula- the fire-resistance-rated floor, floor/ceilingassemblyor <br /> Lion; <br /> the ceiling membrane of a roof/ceiling assembly shall <br /> 1.3. By solid fireblocking in accordance with comply with Sections 714.4.1.1 through 714.4.1.4. Pene- <br /> Section 718.2.1; nations in horizontal smoke barriers shall also comply <br /> 1.4.By protecting both outlet boxes with with 714.5. <br /> listed putty pads;or 714.4.1.1 Through penetrations. Through penetra- <br /> • 1.5. By other listed materials and methods. tions of fire-resistance-rated horizontal assemblies <br /> shall comply with Section 714.4.1.1.1 or 714.4.1.1.2. <br /> 2. Membrane penetrations by listed electrical boxes <br /> of any material, provided such boxes have been Exceptions: <br /> tested for use in fire-resistance-rated assemblies 1. Penetrations by steel, ferrous or copper con- <br /> and are installed in accordance with the instmc- duits, pipes, tubes or vents or concrete or <br /> tions included in the listing. The annular space masonry items through a single fire-resis- <br /> between the wall membrane and the box shall not tance-rated floor assembly where the annular <br /> exceed 1/s inch (3.1 nun)unless listed otherwise. space is protected with materials that prevent <br /> Such boxes on opposite sides of the wall or path- the passage of flame and hot gases sufficient <br /> don shall be separated by one of the following: to ignite cotton waste when subjected to <br /> 2.1. By the horizontal distance specified in the ASTM E 119 or UL 263 time-temperature fire <br /> listing of the electrical boxes; conditions under a minimum positive pressure <br /> differential of 0.01 inch (2.49 Pa) of water at <br /> 2.2. By solid fireblocking in accordance with the location of the penetration for the time <br /> Section 718.2.1; periodequivalent to the fire-resistance rating <br /> 2.3. By protecting both boxes with listed putty of the construction penetrated. Penetrating <br /> pads;or items with a maximum 6-inch(152 mm)nom- <br /> inal By other listed materials and methods. diameter shall not be limited to the pene- <br /> 2.4.3. Membrane tration of a single fire-resistance-rated floor <br /> penetrations by electrical boxes of assembly, provided the aggregate area of the <br /> any size or type,which have been listed as part of openings through the assembly does not <br /> a wall opening protective material system for use exceed 144 square inches(92 900 mm')in any <br /> in fire-resistance-rated assemblies and are 100 square feet(9.3 m2)of floor area. <br /> installed in accordance with the instructions <br /> - included in the listing. 2. Penetrations in a single concrete floor by steel, <br /> ferrous or copper conduits, pipes, tubes or <br /> 4. Membrane penetrations by boxes other than elec- vents with a maximum 6-inch (152 mm)nom- <br /> trical boxes,provided such penetrating items and that diameter, provided the concrete, grout or <br /> the annular space between the wall membrane mortar is installed the full thickness of the <br /> and the box, are protected by an approved mem- floor or the thickness required to maintain the <br /> brane penetration firestop system installed as fire-resistance rating. The penetrating items <br /> tested in accordance with ASTM E 814 or UL shall not be limited to the penetration of a sin- <br /> 1479, with a minimum positive pressure differen- gle concrete floor, provided the area of the <br /> tial of 0.01 inch(2.49 Pa)of water,and shall have opening through each floor does not exceed <br /> an F and T rating of not less than the required 144 square inches(92 900 mm'). <br /> fire-resistance rating of the wall penetrated and <br /> 3. Penetrations by listed electrical boxes of any be installed in accordance with their listing. <br /> material, provided such boxes have been <br /> 5. The annular space created by the penetration of tested for use in fire-resistance-rated assem- <br /> an automatic sprinkler, provided it is covered by blies and installed in accordance with the <br /> a metal escutcheon plate. instructions included in the listing. <br /> 714.3.3 Dissimilar materials. Noncombustible penetrat- 714.4.1.1.1 Installation. Through penetrations shall <br /> ing items shall not connect to combustible items beyond be installed as tested in the approved fire-resistance- <br /> the point of firestopping unless it can be demonstrated that rated assembly. <br /> the fire-resistance integrity of the wall is maintained. <br /> 714.4.1.1.2 Through-penetration p system. <br /> 714.4 Horizontal assemblies. Penetrations of a floor, floor/ Through penetrations shall be protected by an <br /> ceiling assembly or the ceiling membrane of a roof/ceiling approved through-penetration <br /> assembly not required to be enclosed in a shaft by Section firestophASTM <br /> system <br /> saeinstalled and tested in accordance with ASTM E 814 <br /> or UL 1479, with a minimum positive pressure dif- <br /> 2014 OREGON STRUCTURAL SPECIALTY CODE 139 <br />
The URL can be used to link to this page
Your browser does not support the video tag.