My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12989299
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
15-XXXXXX
>
12989299
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 8:00:14 PM
Creation date
7/31/2025 4:12:09 PM
Metadata
Fields
Template:
Permits
Permit Address
6792 SCISM RD NE
Permit City
Silverton
Permit Number
555-15-000086-DWL
Parcel Number
061W30B 01600
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ARE AND SMOKE PROTECTION FEATURES <br /> 4.3. Elevators serving floor levels over 75 feet 714.3.1 Through penetrations. Through penetrations of <br /> (22 860 nun) above the lowest level of fire-resistance-rated walls shall comply with Section <br /> fire department vehicle access in high-rise 714.3.1.1 or 714.3.1.2. <br /> buildings. Exception: Where the penetrating items are steel, fer- <br /> 5. Smoke partitions shall be permitted in lieu of fire rows or copper pipes, tubes or conduits, the annular <br /> partitions to separate the elevator lobby at each space between the penetrating item and the fire-resis- <br /> floor where the building is equipped throughout tance-rated wall is permitted to be protected as follows: <br /> with an automatic sprinkler system installed in 1. In concrete or masonry walls where the penetrat- <br /> accordance with Section 903.3.1.1 or 903.3.1.2. ing item is a maximum 6-inch(152 mm)nominal <br /> In addition to the requirements in Section 710 for diameter and the area of the opening through the <br /> smoke partitions, doors protecting openings in wall does not exceed 144 square inches (0.0929 <br /> the smoke partitions shall also comply with Sec- m2),concrete, grout or mortar is permitted where • <br /> tions 710.5.2.2, 710.5.2.3, and 716.5.9 and duct it is installed the full thickness of the wall or the <br /> penetrations of the smoke partitions shall be pro- <br /> thickness required to maintain the fire-resistance <br /> tected as required for corridors in accordance rating;or <br /> with Section 717.5.4.I. <br /> 2. The material used to fill the annular space shall <br /> 6. Enclosed elevator lobbies are not required where prevent the passage of flame and hot gases suffi- <br /> the elevator hoistway is pressurized in accor- dent to ignite cotton waste when subjected to <br /> dance with Section 909.21. ASTM E 119 or UL 263 time-temperature fire <br /> 7. Enclosed elevator lobbies are not required where conditions under a minimum positive pressure <br /> differential <br /> the elevator serves only open parking garages in of 0.01 inch (2.49 Pa)of water at the <br /> accordance with Section 406.5. location of the penetration for the time period <br /> equivalent to the fire-resistance rating of the con- <br /> 713.14.1.1 Areas of refuge. Areas of refuge shall be struction penetrated. <br /> provided as required in Section 1007. 714.3.1.1 Fire-resistance-rated assemblies. Penetra- <br /> tions shall be installed as tested in an approved fire- <br /> resistance-rated assembly. <br /> * SECTION 714 • <br /> PENETRATIONS 714.3.1.2 Through-penetration firestop system. <br /> Through penetrations shall be protected by an <br /> 714.1 Scope. The provisions of this section shall govern the approved penetration Freston system installed as tested <br /> materials and methods of construction used to protect in accordance with ASTM E 814 or UL 1479, with a <br /> through penetrations and membrane penetrations of horizon- minimum positive pressure differential of 0.01 inch <br /> tal assemblies and fire-resistance-rated wall assemblies. (2.49 Pa)of water and shall have an F rating of not less <br /> than the required fire-resistance rating of the wall pen- <br /> 714.1.1 Ducts and air transfer openings.Penetrations of etrated. <br /> fire-resistance-rated walls by ducts that are not protected <br /> with dampers shall comply with Sections 714.2 through 714.3.2 Membrane penetrations. Membrane penetra- <br /> 714.3.3. Penetrations of horizontal assemblies not pro- Lions shall comply with Section 714.3.1. Where walls or <br /> tected with a shaft as permitted by Section 717.6, and not partitions are required to have a fire-resistance rating, <br /> required to be protected with fire dampers by other sec- recessed fixtures shall be installed such that the required <br /> Lions of this code, shall comply with Sections 714.4 fire-resistance will not be reduced. <br /> through 714.4.2.2.Ducts and air transfer openings that are Exceptions: <br /> protected with dampers shall comply with Section 717. <br /> I. Membrane penetrations of maximum 2-hour tire- <br /> 714.2 Installation details.Where sleeves are used,they shall resistance-rated walls and partitions by steel elec- <br /> be securely fastened to the assembly penetrated. The space trical boxes that do not exceed 16 square inches <br /> between the item contained in the sleeve and the sleeve itself (0.0 103 m2)in area,provided the aggregate area <br /> and any space between the sleeve and the assembly pene- of the openings through the membrane does not <br /> [rated shall be protected in accordance with this section.Insu- exceed 100 square inches(0.0645 m2)in any 100 <br /> lation and coverings on or in the penetrating item shall not square feet (9.29 m') of wall area. The annular <br /> penetrate the assembly unless the specific material used has space between the wall membrane and the box <br /> been tested as part of the assembly in accordance with this shall not exceed 48 inch(3.1 mm).Such boxes on <br /> section. opposite sides of the wall or partition shall be <br /> 714.3 Fire-resistance-rated walls. Penetrations into or separated by one of the following: <br /> through fire walls,fire barriers,smoke barrier walls and fire 1.1. By a horizontal distance of not less than <br /> partitions shall comply with Sections 714.3.1 through 24 inches (610 nun) where the wall or <br /> 714.3.3. Penetrations in smoke barrier walls shall also corn- partition is constructed with individual <br /> ply with Section 714.5. noncommunicating stud cavities; <br /> 138 2019 OREGON STRUCTURAL SPECIALTY CODE <br />
The URL can be used to link to this page
Your browser does not support the video tag.