Permit Address
6792 SCISM RD NE
Permit City
Silverton
Permit Number
555-15-000086-DWL
Parcel Number
061W30B 01600
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRE AND SMOKE PROTECTION FEATURES <br /> • shaft shall be closed off around the penetrating items from the remainder of the building by fire barriers con- <br /> with materials permitted by Section 718.3.1 for structed in accordance with Section 707 or horizontal <br /> I` draftstopping, or the room shall be provided with an assemblies constructed in accordance with Section 711,or <br /> approved automatic sprinkler system. both. Openings into the termination room shall be pro- <br /> 2. A shaft enclosure containing a refuse chute or faun- tected by opening protectives having afire protection rat- <br /> dry chute shall not be used for any other purpose and ing equal to the protection required for the shaft enclosure. <br /> shall terminate in a room protected in accordance Doors shall be self- or automatic-closing upon the deter- <br /> with Section 713.13.4. don of smoke in accordance with Section 716.5.9.3. <br /> Refuse chutes shall not terminate in an incinerator room. <br /> 3. The fire-resistance-rated room separation and the Refuse,recycling and laundry rooms that are not provided <br /> protection at the bottom of the shaft are not required with chutes need only comply with Table 509. <br /> provided there are no combustibles in the shaft and 713.13.5 Incinerator room.Incinerator rooms shall corn- <br /> there are no openings or other penetrations through ply with Table 509. <br /> eras <br /> the shaft enclosure to the interior of the building. <br /> 713.12 Enclosure at top. A shaft enclosure that does not 713.13.E Automatic sprinkler system. An approved <br /> extend to the underside of the roof sheathing,deck or slab of automatic sprinkler system shall be installed in accordance <br /> the building shall be enclosed at the top with construction of with Section 903.2.11.2. <br /> the same fire-resistance rating as the topmost floor pene- 713.14 Elevator,dumbwaiter and other hoistways. Eleva- <br /> trated by the shaft,but not less than the fire-resistance rating tor,dumbwaiter and other hoistway enclosures shall be con- <br /> required for the shaft enclosure. structed in accordance with Section 713 and Chapter 30. <br /> I713.13 Refuse and laundry chutes.In other than Group I-2, 713.14.1 Elevator lobby. An enclosed elevator lobby <br /> refuse and laundry chutes, access and termination rooms and shall be provided at each floor where an elevator shaft <br /> incinerator rooms shall meet the requirements of Sections enclosure connects more than three stories. The lobby <br /> 713.13.1 through 713.13.6. enclosure shall separate the elevator shaft enclosure doors <br /> Exceptions: from each floor by fire partitions. In addition to the <br /> requirements in Section 708 for fire partitions, doors pro- <br /> 1. Chutes serving and contained within a single dwell- tecting openings in the elevator lobby enclosure walls <br /> ing unit. shall also comply with Section 716.5.3 as required for cor- <br /> it gill e <br /> 2. Refuse and laundry chutes in Group I-2 shall com- <br /> ply ridor walls and penetrations of the elevator lobby enclo- <br /> sure by the provisions of NFPA 82,Chapter 5. sure by ducts and air transfer openings shall be protected <br /> as required for corridors in accordance with Section <br /> 713.13.1 Refuse, recycling and laundry chute enclo- 717.5.4.1.Elevator lobbies shall have at least one means of <br /> sures.A shaft enclosure containing a refuse, recycling,or egress complying with Chapter 10 and other provisions <br /> laundry chute shall not be used for any other purpose and within this code. <br /> shall be enclosed in accordance with Section 713.4.Open- <br /> ings into the shaft,including those from access rooms and Exceptions: <br /> termination rooms, shall be protected in accordance with 1. Enclosed elevator lobbies are not required at the <br /> this section and Section 716. Openings into chutes shall level(s)of exit discharge,provided the level(s)of <br /> not be located in corridors. Doors shall be self- or auto- exit discharge is equipped with an automatic <br /> matic-closing upon the actuation of a smoke detector in sprinkler system in accordance with Section <br /> accordance with Section 716.5.9.3, except that heat-acti- 903.3.1.1. <br /> vated closing devices shall be permitted between the shaft 2. Elevators not required to be located in a shaft in <br /> and the termination room. accordance with Section 712.1 are not required to <br /> 713.13.2 Materials.A shaft enclosure containing a refuse, have enclosed elevator lobbies. <br /> i recycling,or laundry chute shall be constructed of materi- <br /> als as permitted by the building type of construction. 3. Enclosed elevator lobbies are not required where <br /> additional doors are provided at the hoistway <br /> I 713.13.3 Refuse, recycling and laundry chute access opening in accordance with Section 3002.6. Such <br /> rooms.Access openings for refuse,recycling and laundry doors shall comply with the smoke and draft con- <br /> chutes shall be located in rooms or compartments enclosed trol door assembly requirements in Section <br /> by not less than 1-hour fire barriers constructed in actor- 716.5.3.1 when tested in accordance with UL <br /> dance with Section 707 or horizontal assemblies con- 1784 without an artificial bottom seal. <br /> strutted in accordance with Section 711, or both. 4. Enclosed elevator lobbies are not required where <br /> Openings into the access rooms shall be protected by the building is protected by an automatic sprin- <br /> opening protectives having a fire protection rating of not kler system installed in accordance with Section <br /> less than 3/4 hour.Doors shall be self-or automatic-closing 903.3 1.1 orstalls 903.3.1.2. This exception shall not. <br /> l upon the detection of smoke in accordance with Section apply to the following: <br /> 6.5.93. <br /> 1 713.13.4 Termination room.Refuse,recycling,and laun- 4.1. Group I-2 occupancies; <br /> dry chutes shall discharge into an enclosed room separated 4.2. Group 1-3 occupancies;and <br /> 2014 OREGON STRUCTURAL SPECIALTY CODE 137 <br />