Plan Review M25-94-2227C <br />Blazer Industries <br /> <br />13. <br /> <br />14. <br /> <br />15. <br /> <br />16. <br /> <br />17. <br /> <br />18. <br /> <br />19. <br /> <br />20. <br /> <br />21. <br /> <br />22. <br /> <br />Plywood shear walls require all panel edges backed with 2 inch nominal or wider framing. <br />1993 OSSC, Table 25-K-1. <br /> <br />Materials exposed within ducts or plenums shall have a flame~spmad rating of not more than <br />25 and a smoke-developed rating of not moro than 50. 1993 OMSC, Section 1002(b). NOTE: <br />Class I rated ducts are required for other than residential occupancies. <br /> <br />Supply and retum ducts in unheated spaces are to be insulated in accordance with the <br />1993 OSSC, Table 53(k) and 1993 OMSC, Table 10-D. <br /> <br />HVAC unit shall be installed in accordance with the manufacturer's listed installation <br />instructions. Clearances to supply plenum shall receive particular attention. Provide instructions <br />with unit when skipped. 1993 OMSC, Section 504(a). <br /> <br />Zinc-coated (galvanized) metal sheets intended for roofing and/or siding shall have a zinc <br />coating weighing not less than 1.25 ounces per square foot. 1993 OSSC, Section 3208(b)(6) <br />and 1988 BBC Standard 32-4, Section 32.410. Metal roof installation shall be in accordance <br />wkh manufacturer's installation instructions for wind criteria shown under design. <br /> <br />Bathroom exhaust fans shall be vented to the outside in non-combustible, non-absorbent ducts <br />and shall be equipped with backdraft dampers. 1993 OMSC, Section 1104. <br /> <br />Plans, specifications, and other requested data shall be provided to the local building official <br />for his inspection of the foundation system, utility connections, and the "marriage" of multiple <br />component structures. Other site work performed on the unit itself (other than the <br />above-mentioned) will requlxe an incomplete systems agreement (NLEA). <br /> <br />All plumbing, wiring, heating, and structural work below the level of the modular unit (bottom <br />of floor joists), shall be site-permitted and site-inspected. <br /> <br />In dwelling units (i.e. OSSC), a detector shall be installed in each sleeping room and at a point <br />centrally located in the corridor or area giving access to each separate sleeping area. <br />1993 OSSC, Section 1210(a)4. <br /> <br />Provide 24" of knee room in front of water closets. Water closet compartments shall be 30" <br />in width minimum finished dimension. "Open fronts and elongated bowls are required for other <br />than private use.' 1992 OPSC, Section 901 and 907(0. <br /> <br /> <br />