My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 1312
Images9
>
Public Works - Planning
>
FOR PUBLIC VIEW ON INTERNET
>
Old Cases
>
Ord 1312
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2022 9:14:53 AM
Creation date
10/30/2024 3:18:23 PM
Metadata
Fields
Template:
Land Use
Case_Number
07-007
Document_Date
12/3/2008
Land Use Type
Subdivision
Tax_Lot_Number
082W30 00400
Document_Type
Decision
Site_Address
3710 BERGMAN PL SE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
applicant proposes to upgrade an existing water well to provide a safe reliable water supply; construct <br /> a chlorine gas disinfection and monitoring facility; construct a community water distribution system <br /> including approximately 20,000 linear feet of eight to four-inch C-900 PVC water main, 47 fire <br /> hydrants, and 63 isolation valves; pressure booster system for 10 homes; and minimum 100,000 gallon <br /> water storage reservoir that meets Stayton Fire District fire flow requirements and provides two days <br /> of emergency storage. The complete system will be incrementally disinfected and pressure tested prior <br /> to placement in service. <br /> The Board relies on the evidence in the record, including the testimony by the applicant and the <br /> letter from Steven Shropshire, dated January 10, 2008, and finds that it is feasible for this condition to <br /> be met. To ensure compliance, the Board imposes Condition No. 13. <br /> 5. The community sewer system shall meet the requirements of the State Department of <br /> Environmental Quality. <br /> The Board relies on the evidence in the record, including the testimony of the applicant, stating <br /> that it has met with the Department of Environmental Quality and the County Public Works <br /> Department to discuss the proposed wastewater collection, treatment and disposal system. To provide <br /> wastewater treatment and disposal for initial development, a community septic tank drainfield is <br /> proposed. The Board finds that as development occurs and warrants, the following improvements will <br /> be constructed: individual septic tank drainfield systems for two houses, a community wastewater <br /> collection system consisting of approximately 18,000 linear feet of eight-inch gravity sewer main, <br /> .80 manholes, 3,100 linear feet of 4-inch pressure main, 50,000 gallon per day membrane bioreactor <br /> wastewater treatment plant, effluent storage lagoon and effluent irrigation/disposal system. Standby <br /> emergency, electric power generation will be included in the wastewater treatment plant to ensure <br /> continuous wastewater treatment and storage. <br /> The Board relies on the evidence in the record, including testimony by the applicant and the <br /> letter from Steven Shropshire, dated January 10, 2008 and the letters from Tracy Cork, dated <br /> December 10, 2007 and June 12, 2008 and finds that it is feasible for this condition to be met. To <br /> ensure compliance, the Board imposes Condition No. 2. <br /> 6. All utilities shall be placed underground. Five-foot utility easements shall be provided <br /> on both sides of all private roads and in other locations requested by the telephone and power <br /> companies. <br /> The Board relies on the evidence in the record, including the testimony by the applicant, stating <br /> that all utilities will be placed in easements located alongside private roads and that these easements <br /> will be shown on the Final Plat for each phase. The Board finds that it is feasible for this condition to <br /> be met. <br /> 7. The maximum number of dwelling shall be 196. The 150 single-family lots proposed on <br /> the 137 acres shall not be less than 6,000 square feet in area and have at least 20 feet of frontage on a <br /> private road. The location of the lots shall generally conform to the conceptual development plan. A <br /> final development plan showing the location of buildings,parking, access, drainage, and landscape <br /> area shall be approved by the Department of Public Works and Planning Director prior to <br /> construction. If any portion of the 12 acres is divided into smaller lots to be owned by someone other <br /> than the homeowners association, the proposed lot sizes and configurations shall be subject to detail <br /> subdivision approval. The number of single-family or condominium units may be adjusted within the <br /> -28- <br />
The URL can be used to link to this page
Your browser does not support the video tag.