• <br /> • Within a few seconds,the audible alarm • The Recirc pump should complete the Redundant Off&Low Level Alarm(bottom <br /> should shut off and the alarm light minimum override cycles(default is float): This float turns off the Discharge pump when <br /> should be flashing. three) and then return to its normal cycle lowered. This float is a secondary off float,which <br /> • The Recirc pump will start to cycle in time. will operate if the Timer On&Off float fails. This <br /> approximately 36 second intervals, • The Recirc pump should continue float also activates the alarm light(steady) and <br /> starting with the off cycle. cycling as indicated by digital output#1, audible alarm when lowered. The audible alarm may <br /> • Digital output#1 and digital input#6 and input#6 being illuminated. be silenced by pressing the illuminated"Hold-To- <br /> should be illuminated during the on • Digital input#1 should remain Silence"button on the front of the control panel. The <br /> cycle. illuminated,indicating that the bottom alarm light will remain steady until the float is lifted. <br /> float is in the up position. <br /> S Pump &Valve Operation(for Test Mode Only): <br /> 2. Override Timer Float Test 0 Reinstall the Recirc float assembly into the The pump dosing cycles will be controlled by the <br /> O Lift and secure the middle float in the up pump vault. Ensure that the floats are free timer.During high flow conditions,the pump dosing <br /> position. from entanglements(e.g.,float cords,etc). cycles will be controlled by the override timer.A <br /> • Digital inputs#1 and#2 should be complete cycle of the Discharge pump will operate as <br /> illuminated. 0 Ensure that the tank has enough water to follows: <br /> • The Recirc pump cycle will shorten to 24 maintain the RO (bottom)float in the up • Off Cycle;pump is deactivated. <br /> second intervals. position(Required for Cut-off Test). • On Cycle;pump is activated. <br /> • Digital output#1 and digital input#6 • Drip Flush;activated simultaneously <br /> should illuminate when the Recirc pump 0 The Recirc pump should continue to cycle during first minute of on cycle. <br /> is on. during the Discharge test. • Spinfilter Flush;pump remains activated <br /> while the spinfilter valve is open at the end <br /> 3. High Level Alarm Float Test - Discharge Float Test of the on cycle to allow for spinfilter <br /> ❑ Lift and secure the top float in the up While in test mode,the Discharge floats will function flushing. <br /> position. as described: <br /> • Digital inputs#1,#2,and#3 should be To perforin the following test,sufficient effluent is <br /> illuminated. High Level Alarm/Override Timer On/Off(top required. If there is not enough effluent in the <br /> • The audible alarm and alarm light float): This float activates the alarm light(steady) Discharge Tank,turn the Discharge pump circuit <br /> (steady)should activate. Digital outputs and audible alarm when lifted. Pressing and holding breaker off. <br /> #3,and#4 should illuminate. the illuminated"Hold-To-Silence"button on the <br /> front of the control panel will silence the audible To test the functionality of the Discharge floats and <br /> O Drop the top float and ensure that it is in the alarm. The alarm light will remain steady until the ensure that the panel is installed correctly,follow the <br /> down position. float is lowered.This float also activates the override steps below: <br /> • Within a few seconds,the audible alarm timer when lifted. The override timer controls the <br /> should shut off and the alarm light pump during high flow conditions. The override 1. RO/Low Level Alarm Float Test <br /> should be flashing. timer function will remain active until the set 0 Pull the Discharge float assembly out of the <br /> • Digital output#4 should NOT be minimum number of override cycles has been pump vault and position it so that all the <br /> illuminated. completed and the float has lowered. floats are in the down position. <br /> • The Recirc pump should continue • The bottom float relay indicator light and <br /> cycling as indicated by digital output#1, Timer On/Off(middle float): This float enables the digital inputs#4,and#5 should NOT be <br /> and input#6 being illuminated. timer function when lifted.,The timer function illuminated. <br /> controls the pump during normal flow conditions. • The alarm light(steady)and audible <br /> 4. Returning To Normal Cycle Time Note: The timer will start with its off cycle. alarm should activate. <br /> O Drop the middle float and ensure that it is <br /> now in the down position. <br /> EIN-CP-OP-2109 <br /> Rev 1.1©04/12/10 <br /> Page 4 of 5 <br />