• The Discharge low level alarm float is • The Discharge low level alarm float is the set minimum number of override cycles has been <br /> up(the float relay indicator light is up(the rain sensor relay indicator is completed and the float has lowered. <br /> illuminated). . illuminated). <br /> • The Rain Sensor input is made(the rain • The UV system is operating correctly. Redundant Off&Low Level Alarm(bottom <br /> sensor relay indicator light is - float): <br /> illuminated). ❑ Force the rain sensor to output as if water has This float enables the timer function when lifted. The <br /> been detected(the rain sensor relay indicator timer function controls the pump during normal flow <br /> 0 Force the LTV light to fail.This is done by light should NOT be illuminated). conditions. Note: The timer will start with its off <br /> switching the UV circuit breaker to OFF. cycle. This float disables the pump and activates the <br /> • The LED display on the UV current ❑ The alarm light,on the front of the panel alarm light(steady)and the audible alarm when <br /> sensor should begin blinking and display should change from flashing to steady. ' lowered. The audible alarm may be silenced by <br /> a value of zero. • If the alarm did not change state there is pressing the illuminated"Hold-To-Silence"button on <br /> a possible problem with the rain sensor. the front of the control panel.'The alarm light will <br /> ❑ The alarm light on the front of the panel remain steady until the float is lifted. <br /> should change from flashing to steady. ❑ The discharge pump will not be cut-off while <br /> • If the alarm did not change state there is in test mode.The discharge pump WILL be To perforin the following test,sufficient effluent is <br /> a possible problem with: cut-off during normal operation.If the required. If there is not enough effluent in the <br /> 1. The UV light,or Discharge pump should NOT be cut-off by Recirc Tank,turn the Recirc pump circuit breaker <br /> 2. The setpoint on the current sensor, the rain sensor, off. <br /> or • The-VCOM board will need to be <br /> 3. The current sensor itelf. connected to directly or through the web, To test the.functionality of the Recirc floats and <br /> • and ensure that the panel is installed correctly,follow the <br /> ❑ The discharge pump will not be cut-off while • Point#55 will need to be changed from steps below: <br /> in test mode.The discharge pump WILL be Y to N. • <br /> cut-off during normal operation.If the <br /> Discharge pump should NOT be cut-off when CIIf connection to a rain sensor can not be made 1. RO/Low Level Alarm Float Test <br /> the UV light fails, immediately,then an insulated jumper wire ❑ Pull the Recire float assembly out of the <br /> • The VCOM board will need to be will need to be installed between terminals pump vault and position it so that all the <br /> connected to directly or through the web, #17 and#18 before continuing. floats are in the down position. <br /> and <br /> • Point#58 will need to be changed from Recirc Float Test ❑ If the Discharge high level(top)float is lifted <br /> Y to N. While in test mode,the Recire floats will function as (digital input#5 is illuminated),then pull the <br /> described: Discharge float assembly out of the pump <br /> ❑ Turn on the UV circuit breaker vault and position it so the bottom float is up <br /> High Level Alarm(top float): This float activates and the other floats are down. <br /> Rain Sensor Test the alarm light(steady)and audible alarm when • Digital inputs#1,#2,#3,and#5 should <br /> lifted. Pressing and holding the illuminated"Hold- NOT be illuminated. <br /> ❑ Verify that all other alarms are cleared. To-Silence"button on the front of the control panel • The alarm light(steady) and audible <br /> • The Recire.RO float is up(digital input will silence the audible alarm. The alarm light will alarm should activate. <br /> #1 should be illuminated). remain steady until the float is lowered. <br /> • The Recirc.high level alarm float is ❑ Lift and secure the bottom float in the up <br /> down(digital input#3 should NOT be Override On/Off(middle float): This float position. <br /> illuminated), activates the override timer when lifted. The override • Digital input#1 should be illuminated. <br /> • The Discharge high level alarm float is timer controls the pump during high flow conditions. <br /> down(digital input#5 should NOT be The override timer function will remain active until <br /> illuminated). <br /> EIN-CP-OP-2109 <br /> • <br /> Rev 1.1©04/12/10 <br /> Page 3 of 5 <br />