Laserfiche WebLink
n,., J:,_,,+3, x,,,'vt G is _,'• ,, " :` .s+. r`�'�.,6 `c�5 ,,;,:,,...14: _ cv.. ).wf�ff-*f V i At m. _ �::i`R`-ter r,.. ..t <br /> retic - 9 „, , P.l}.§i.'�”{..Y 1Cl AC'�""w/�'sy FL'Y9 j"�f.- 'y-6 . j� 's}- <br /> :4*.imm <br /> .S A h'i `R �i+'� 'ALt "}W_ 1 fi' Vf." T.Sir.. !.t 4 �-,� ol <br /> ✓} '� rY H f Y l Y Ao .., l'v�rv� NE =] T,�i.> �.zni..it'GS�41) t `t'Y.�: <br /> tti <br /> Ka1 <br /> ::nark1.01:41,1t�AMi <br /> { 1 1 a <br /> of r'I fill <br /> 4 �ia1t� <br /> l ' tli ; , , <br /> \ / cV--1°E.-_,Itm-444. w.0,-L--_,1,) <br /> Oieiic MVP-DAXIDli•1 120V panel <br /> Standard Components <br /> Feature Specification(s) <br /> 1.Programmable Logic Unit 120 VAC programmable logic unit with built-in LCD screen and programming keys.Provides control functions and timing for panel operation. <br /> 2.Motor-Start Contactors 120 VAC:16 FLA,1 hp(0.75 kW),60 hz;2.5 million cycles at FLA(10 million at 50%of FLA) <br /> 240 VAC:16 FLA,3 hp(2.24 kW),6011z;2.5 million cycles at FLA(10 million at 50%of FIA) <br /> 3.Toggle Switches Single-pole,double-throw HOA switch.20 A,t hp(0.75 kW). <br /> 4.Controls Circuit Breaker 10A,OFF/ON swish.Single-pole 120 V'.DIN rail mounting with thermal magnetic tripping characteristics. <br /> 5.Pump Circuit Breakers 20 A,OFF/ON switches.Single-pole 120 V or double-pole 240 V.DIN rail mounting with thermal magnetic tripping characteristics. <br /> 6.Audible Alarm 95 dB at 24 in.(610 min),warble-tone sound. <br /> 7.Visual Alarm 7/8-in.(22-min)diameter red lens,"Push-to-slence."UL Type 4X rated,1 W LED not,120 VAC. <br /> 8.Panel Enclosure Measures 11.5 in.high x 9.5 in.wide x 5.4 in.deep(290 x 240 x 135 mm).UL Type 4X rated.Constructed of UV-resistant fiberglass; <br /> hinges and latch are stainless steel.Conduit couplings provided. <br /> Dual-Mode Operation Programmable for tuned-and demand-dosing. <br /> MVP-DAX1 DM Pariel Ratings 120 VAC,1 hp(0.75 INV),16 A,single phase,6011z. <br /> MVP-DAX2DM Panel Ratings 240 VAC,3 hp(2.24 kW),16 A,single phase,8011z. <br /> Optional Components <br /> Feature Specification(s) Product Code Adder <br /> Intrinsically Safe Control Relays 120 VAC.Listed per UL 698A,for Class 1 Div1,Groups A,B.C,D hazardous locations.larger enclosure required. IR <br /> Current Sensor 120 VAC.Go/no-go operation.Pump fail Indicator light on panel.Manual reset switch. CS <br /> Heater Anti-condensation heater.Self-adpusting:radiates additional wattage as temperature drops. M <br /> Pump Run Lights 7,8-in.(22-mm)diameter green lens.UL Type 4X rated,1 W LED light,120 VAC. - PRI- <br /> Power Light 7/8-in.(22-mm)ltiaineter green lens.UL Type 4X rated,1 W LED light,120 VAC. PL <br /> Surge Arrestor 120 V.Status light on unit.Protects incoming power supply from electrical suiges. SA <br /> 2.40 VAC units available for inn nwlkets <br /> " 1211 V AC Whist lin smote alaww cotni6 standard. <br /> NM-CP-MVP-2 Orono Systems°Inc,,814 Atrway Ave.,Suthertin,OR 97479 USA•800-348-9843•541-459-4449•www.orence.cam <br /> flee.2.0,O 03117 <br /> Page 2 or 2 <br />