<br /> Oieiic MVP-DAXIDli•1 120V panel
<br /> Standard Components
<br /> Feature Specification(s)
<br /> 1.Programmable Logic Unit 120 VAC programmable logic unit with built-in LCD screen and programming keys.Provides control functions and timing for panel operation.
<br /> 2.Motor-Start Contactors 120 VAC:16 FLA,1 hp(0.75 kW),60 hz;2.5 million cycles at FLA(10 million at 50%of FLA)
<br /> 240 VAC:16 FLA,3 hp(2.24 kW),6011z;2.5 million cycles at FLA(10 million at 50%of FIA)
<br /> 3.Toggle Switches Single-pole,double-throw HOA switch.20 A,t hp(0.75 kW).
<br /> 4.Controls Circuit Breaker 10A,OFF/ON swish.Single-pole 120 V'.DIN rail mounting with thermal magnetic tripping characteristics.
<br /> 5.Pump Circuit Breakers 20 A,OFF/ON switches.Single-pole 120 V or double-pole 240 V.DIN rail mounting with thermal magnetic tripping characteristics.
<br /> 6.Audible Alarm 95 dB at 24 in.(610 min),warble-tone sound.
<br /> 7.Visual Alarm 7/8-in.(22-min)diameter red lens,"Push-to-slence."UL Type 4X rated,1 W LED not,120 VAC.
<br /> 8.Panel Enclosure Measures 11.5 in.high x 9.5 in.wide x 5.4 in.deep(290 x 240 x 135 mm).UL Type 4X rated.Constructed of UV-resistant fiberglass;
<br /> hinges and latch are stainless steel.Conduit couplings provided.
<br /> Dual-Mode Operation Programmable for tuned-and demand-dosing.
<br /> MVP-DAX1 DM Pariel Ratings 120 VAC,1 hp(0.75 INV),16 A,single phase,6011z.
<br /> MVP-DAX2DM Panel Ratings 240 VAC,3 hp(2.24 kW),16 A,single phase,8011z.
<br /> Optional Components
<br /> Feature Specification(s) Product Code Adder
<br /> Intrinsically Safe Control Relays 120 VAC.Listed per UL 698A,for Class 1 Div1,Groups A,B.C,D hazardous locations.larger enclosure required. IR
<br /> Current Sensor 120 VAC.Go/no-go operation.Pump fail Indicator light on panel.Manual reset switch. CS
<br /> Heater Anti-condensation heater.Self-adpusting:radiates additional wattage as temperature drops. M
<br /> Pump Run Lights 7,8-in.(22-mm)diameter green lens.UL Type 4X rated,1 W LED light,120 VAC. - PRI-
<br /> Power Light 7/8-in.(22-mm)ltiaineter green lens.UL Type 4X rated,1 W LED light,120 VAC. PL
<br /> Surge Arrestor 120 V.Status light on unit.Protects incoming power supply from electrical suiges. SA
<br /> 2.40 VAC units available for inn nwlkets
<br /> " 1211 V AC Whist lin smote alaww cotni6 standard.
<br /> NM-CP-MVP-2 Orono Systems°Inc,,814 Atrway Ave.,Suthertin,OR 97479 USA•800-348-9843•541-459-4449•www.orence.cam