3400149
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
07-XXXXX
>
3400149
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2013 5:05:44 PM
Creation date
11/26/2010 9:58:09 AM
Metadata
Fields
Template:
Permits
Permit Address
11957 TOWERS RD SE
Permit City
STAYTON
Permit Number
555-07-09207
Parcel Number
091E16D 01200
Permit Type
DWELL
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br />Building Inspection Division <br />Incomplete Plans Notice <br />Residential <br /> <br /> <br /> <br /> <br /> <br /> Application Number: 07-09207 Date: December 13, 2007 <br /> <br /> Project Address: 11957 SE Towers Rd. ST <br /> <br />Preliminary Check of Submitted Documents: LS <br /> <br />ONE & TWO FAMILY DWELLING PERMIT APPLICATION CHECKLIST <br />APPROVED CHECKLIST FOR COMPLIANCE WITH OAR 918-090-0320 <br /> <br /> <br />The following items are required for plan review and shall be used by the jurisdiction to determine <br />a complete set of plans and compliance with OAR 918-020-0090(3)(a)(C) and (4). <br /> <br />Received Missing <br /> <br />1 Two Complete sets of legible plans <br /> dawn to scale, showing conformance to the applicable local <br />and state building codes. Lateral design details and connections must be incorporated into the plans <br />or on a separate full size sheet attached to the plans with cross-references between plan location and <br />details. Plan review cannot be completed if copyright violations are evident <br />1a <br />2 Site/Plot plan drawn to scale. <br />The plan must show: lot and building setback dimensions; property <br />corner elevations (if there is more than 4-ft. Elevation differential, the site plan must show contour <br />lines at 2-ft. Intervals for a distance away from the building necessary to show compliance with <br />OTFDC Sec 401); location of easements and driveway, footprint of structure (including decks), <br />location of wells/septic systems, utility locations, any known fill sites or landslide hazard areas, <br />direction indicator, lot area, impervious area, existing structures on site, and surface drainage. <br />2a <br />3 Foundation Plan and Cross Section <br />. Show footing and foundation dimensions, anchor blots, any <br />hold-downs and reinforcing steel, connection details, foundation vent size and location, and soil <br />type. <br />3a <br />4 Floor plans <br />. Show all dimensions, room identification, door and window sizes and locations, <br />location of smoke detectors, water heater, HVAC equipment, ventilation fans, plumbing fixtures, <br />balconies and decks 30 inches above grade; etc. <br />4a <br />5 Cross Section(s) and Details <br />. Show all framing member sizes and spacing such as floor beams, <br />headers, joists, sub-floor, wall construction, roof construction. More than one cross section may be <br />required to clearly portray construction. Show details of all wall and roof sheathing, roofing, roof <br />slope, ceiling height, siding material, footings and foundations, stairs, fireplace construction, <br />thermal insulation, etc. <br />5a <br />6 Elevation Views <br />. Provide elevations for new construction; minimum of two elevations for <br />additions and remodels. Exterior elevations must reflect the actual grade if the change in grade is <br />greater than 4 ft. at building envelope. Full size sheet addendums showing foundation elevations <br />with cross-references are acceptable. <br />6a <br />7 Wall Bracing (Prescriptive Path) and/or Lateral Analysis Plans <br />. Building plans must show <br />construction details and location of lateral brace panels; for non-prescriptive path analysis provide <br />specifications and calculations to engineering standards <br />555 Court St. NE Room 2260 ~ P.O. Box 14500 ~ Salem, Oregon 97309-5036 ~ Phone (503) 588-5147 ~ Fax (503) 588-7948 <br /> <br />Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.