My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1616006
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1616006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2013 8:36:12 AM
Creation date
4/3/2005 1:13:20 PM
Metadata
Fields
Template:
Permits
Permit Address
12175 WEST STAYTON RD SE
Permit City
Aumsville
Permit Number
555-99-06180
Parcel Number
091W18C 01700
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Phone: (503) 58,9-1727 Fax: (503) 589-!728, <br /> <br />POST FRAME BUILDING CONSTRUCTION NOTES <br /> <br />Project No: <br />Date: <br />Client: <br />Owner: <br />Address: <br /> <br />99-241 <br />May 18,1999 <br />Kelly Pdnce <br />Kelly Pdnce <br />12175 W. Stayton Rd. ~//.~/~/[~,f~,aj~' <br />Stayton, OR 97325 u/ZAW.,O~, <br /> C~/~ <br /> EXPIRES: ' ~ ~, I ~'~ <br /> <br />1. All concrete rc shall be 2500 psi minimum at 28 days. The concrete shall be mixed <br /> in the correct proportions prior to placement. No special inspection is required. <br /> <br />All framing lumber shall be at least the minimum noted on the drawings. Lumber not <br />specifically called out may be Standard or better. No. 2 DOUG-FIR may be <br />substituted for No. 2 HEM-FIR. <br /> <br />3. Insure that ALL lateral bracing required by the manufacturer of the pre-engineered <br /> trusses have been installed in accordance with the manufacturer's instructions. <br /> <br />4. Install the posts to the depth given in the drawings. Install a 6' thick (min) concrete <br /> pad in each posthole. The posthole diameter shall be as noted in the drawings. The <br /> posts shall be cantered on the footings. The contractor shall insure that the backfill <br /> in the postholes is cast against undisturbed soil. <br /> <br />5. If the drawings specify concrete backfill in the postholes, install (10) 20d galvanized <br /> nails 2' deep into two opposite post faces on the embedded area of the post. <br /> <br />If the drawings specify granular backfill in the postholes, the backfill shall be 518" to <br />3/4' (-) gravel or crushed rock. The contractor shall insure that the backfill is <br />saturated prior to backfilling and is compacted after each 6" lift. <br /> <br />If the drawings specify natural backfill in the postholes, the backfill shall be well- <br />graded native soil (free from all organics and large cobbles). The contractor shall <br />insure that the backfill is saturated prior to backfilling and is compacted after each <br />lift. <br /> <br />8. If the drawings specify sand backfill in the postholes, the contractor shall insure that <br /> the sand is saturated prior to backfilling and is compacted after each 6' lift. <br /> <br />9. Install all steel sheathing to the interior framing members (girts and purlins) per the <br /> Typical Screw Schedule given on the Standard Details drawing unless noted <br /> otherwise. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.