Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />01/29/99 09:41 PERMIT NO : 98-10985 <br />Resident, addition/alteration STATUS : ISSUED <br />R-2 ISSUED : 01/29/1999 <br />V-N TO EXPIRE : 07/28/1999 <br /> 4 <br /> <br /> PAGE : <br /> switched, Smoke detectors shall be permitted to be battery <br /> operated when installed in existing buildings without <br /> commercial power or in buildings which undergo alterations, <br /> repairs or additions regulated by Section 216,11 <br /> [Sec, 216,2] <br />22, BATHROOM LIGHT / VENT, Bathrooms, water closet compartments <br /> and other similar rooms shall be provided with a window of <br /> not less than 2 square feet, one half of which must be <br /> openable, or artificial light and an approved mechanical <br /> ventilation system capable of producing a change of air <br /> every 12 minutes. [Sec, 202,2] <br />24. ATTIC VENTS, Provide screened attic vents with a net free <br /> area of 1/150 of the attic area (or 1/200 if between 50 of <br /> 80 percent of required area is ventilators in the upper <br /> portion of the attic and located at least 2 feet above eave <br /> or cornice vents), As an alternative, install a 1 mil vapor <br /> barrier on the warm side of the ceiling. [Sec. 806.2] <br />25, ATTIC ACCESS. A readily accessible attic access shall be <br /> provided to any attic area having a clear height of over <br /> 20 inches. A framed opening not less than 22 inches by <br /> $0 inches is required. [Sec, 807,1] <br /> <br /> <br />