Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />01/29/99 09:41 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-2 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-10985 <br />ISSUED <br />01/29/1999 <br />07/28/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 5 Right: 5 Rear: 24 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br /> 2. THIS PLAN REVIEW WAS COMPLETED BY D. MARET ON 1-29-99, <br /> 3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 4. LOT DP~qINAGE. Lots shall be provided with adequate drainage <br /> and shall be graded so as to drain surface water away from <br /> foundation walls, The grade away from foundation walls shall <br /> fall a minimum of 6 inches within the first lO feet, Where <br /> lot lines, walls or other physical barriers prohibit <br /> 6 inches of fall within 10 feet. drains or other approved <br /> means shall be provided to ensure positive drainage, <br /> [Sec, 401,2] <br /> 5, FOUNDATION CRIPPLE WALLS shall be framed of studs not less <br /> in size than the studding above. When exceeding 4 feet, such <br /> walls shall be framed of studs having the size required for <br /> an additional story, [Sec. 602,8] <br /> 6. FOUNDATION CRIPPLE WALLS less than 14 inches in height shall <br /> be sheathed with wood structural panels attached to both the <br /> top and bottom plates in accordance with Table 602.3a or <br /> shall be constructed of solid blocking. [Sec, 602.8.1] <br /> 7. CRAWL HOLE. provide access through the floor or existing fou <br /> ndation to the new family addition. Minimum size shall be <br /> 18" x 24". (SEC, 409.2) <br /> 8. UNDERFLOOR DRAINS, The finished grade of the underfloor <br /> surface may be located at the bottom of the footing: however <br /> where there is evidence that the groundwater table can rise <br /> to within 6 inches of the finished floor at the building <br /> perimeter or where there is evidence that the surface water <br /> does not readily drain away from the building site, the <br /> grade in the underfloor space shall be as high as the <br /> outside finished grade, unless an approved drainage system <br /> is provided, [Sec. 409,4] <br /> 9. THE TJI FLOOR joist system shall be installed in accordance <br /> with its listing and the manufacturer's installation in- <br /> structions, Please have the installation instructions <br /> available during the framing inspection, <br />lO. BP, ENG. This structure uses Braced Panels and an Engineered <br /> Design to meet the lateral bracing requirements of the code. <br /> Insure that all BP's and Engineered Design require~nts are <br /> located as indicated on the plans and constructed as shown <br /> on the plans and on the attached engineering sheets, <br />Il, WATER DISPERSAL. When dwellings have a controlled method of <br /> water disposal from roofs, all roof drainage shall be <br /> collected and discharged to the ground surface at least 5 <br /> feet from the foundation walls, or to an approved drainage <br /> system. [Sec. 801.3, 801.4] Approved drywells must be <br /> located at least lO feet from the building. <br />12. TRUSS DESIGN, Roof trusses are required to be be designed by <br /> an Oregon registered Engineer or Architect. For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspection. All jobsite cutting or <br /> modifications of the roof trusses shall be clearly shown in <br /> the engineer's design calculations and drawings, <br />13. HEADERS. The maximum span for a 4" x 8" header is 8 feet: if <br /> spanning 10 feet use a minimum of 2" x lO". (SEC. 602,6) <br />14, SAFETY GLAZING / VARIOUS. The following shall be considered <br /> specific hazardous locations for the purposes of glazing, <br /> <br /> <br />