My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1532011
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1532011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2013 1:46:17 PM
Creation date
12/29/2004 8:51:22 AM
Metadata
Fields
Template:
Permits
Permit Address
8794 SHAW SQ SE
Permit City
Aumsville
Permit Number
555-99-00018
Parcel Number
082W24B 01400
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BUILDING PERMIT <br />DATE/TIME 04/22/99 08:16 <br />TYPE Residential accessory struct <br />OCCUPANCY S-3 <br />CONST TYPE V-N <br />UGB: SITE: FD <br /> <br />PERMIT NO <br />STATUS <br />ISSUED <br />TO EXPIRE <br />RAGE <br /> <br />99-00018 <br />ISSUED <br />04/22/1999 <br />10/19/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center~ <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br /> 2, THIS PLAN REVIEW WAS COMPLETED BY DWALTERS on 4/21/99. <br /> 1996 CODE, <br /> 3, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 4. Approved for private non-commercial use only, <br /> 5. THIS WILL BE A PRIVATE GARAGE ON THE FIRST FLOOR WITH HOUSE- <br /> HOLD STORAGE WITH A 40# FLOOR ON THE SECOND, THERE WILL BE A <br /> COMPLETE SEPERATION BETWEEN THE FIRST AND SECOND FLOOR WITH <br /> 1/2" (MINIMUM) SHEETROCK AND A 20 MINUTE FIRE DOOR OR A <br /> SOLID 1 3/8" WOOD DOOR. (MINIMUM) <br /> THE ABOVE INFORMATION AS PER A PHONE CONVERSATION WITH <br /> LAROY GOSSEN 4:00 4/14/99, <br /> 6. THIS STRUCTURE USES FLOOR TRUSSES FROM ACTION TRUSS FOR THE <br /> LOFT FLOOR. THE ENGINEERING AND THE INSTALLATION INSTRUCTIO <br /> NS NEED TO BE AVAILABLE TO THE INSPECTOR AT THE TIME OF THE <br /> FRAMING INSPECTION. THE INSPECTION CANNOT BE COMPLETED WITH <br /> OUT THIS INFORMATION, <br /> 7. THE LATERAL DESIGN. THE BEAMS AND STUDS, AND THE DESIGN DF <br /> THE FOUNDATION ARE ALL ENGINEERED BY: <br /> MIKE SALITURO, P.E. # 8682 OR PERHAPS 6682. <br /> 8. LOT DRAINAGE, Lots shall be provided with adequate drainage <br /> and shall be graded so as to drain surface water aw~y from <br /> foundation walls, The grade away from foundation walls shall <br /> fall a minimum of 6 inches within the first 10 feet, Where <br /> lot lines, walls or other physical barriers prohibit <br /> 6 inches of fall within 10 feet, drains or other approved <br /> means shall be provided to ensure positive drainage. <br /> [Sec. 401.3] <br /> 9. GROUNDING ELECTRODES. When concrete reinforcing bars are <br /> installed in concrete footings, the following requirements <br /> shall be met to provide for a grounding electrode system: <br /> 1. Uncoated No. 4 reinforcing bar installed not less <br /> 20 feet in length encased with a minimum of 2 inches of <br /> concrete. <br /> 2, An uncoated No. 4 reinforcing bar stubbed up at least <br /> 12 inches above the floor plate line and tightly attached to <br /> the reinforcing bar located in the footing. The spliced lap <br /> of the staubbed up bar to the footing shall be a minimum of <br /> 12 inches, (See Section 4108,1,2) [Sec. 402,4] <br />10. CUT SLOPES, Slopes for permanent fills and cut slopes for <br /> permanent excavations shall not be steeper than two units <br /> horizontal to one unit vertical. A steeper cut slope may be <br /> extablished only after presentation of a soil investigation <br /> report acceptable to the Building Official, [Sec. 401.5] <br />11, BUILDINGS / SLOPES. The placement of buildings and <br /> strucutres on or adjacent to slopes steeper than three units <br /> horizontal to one unit vertical shall be in accordance with <br /> the code, [Sec. 401,6] <br /> IF THE SITE IS STEEPER THAN 3 TO L, DO NOT START CONSTRUCTIO <br /> N UNTIUL YOU HAVE SUBMI~ED TO THIS OFFICE INFORMATION AS TO <br /> HOW STEEP THE BUILDING SITE ACTUALLY IS. THERE MAY BE OTHER <br /> CODE CONCERNS THAT NEED TO BE ADDRESSED, <br /> CALL WITH QUESTIONS, <br />12, DRAINS shall be provided around all concrete or masonry <br /> foundations enclosing habitable or usable spaces located <br /> below grade, Perforated pipe or other approved systems or <br /> materials shall be installed at or below the area to be <br /> <br /> <br />