My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1523046
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1523046
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2013 1:51:40 PM
Creation date
12/13/2004 7:48:52 AM
Metadata
Fields
Template:
Permits
Permit Address
13544 EHLEN RD NE
Permit City
Aurora
Permit Number
555-98-07644
Parcel Number
041W11C 01701
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: <br /> <br /> BUILDING PERMIT <br /> 10/05/98 08:09 <br /> Resident. addition/alteration <br /> R-3 <br /> V-N <br />SITE: FD <br /> <br />12, <br /> <br />14. <br /> <br />16, <br /> <br />PERMIT NO <br />STATUS <br />ISSUED <br />TO EXPIRE <br />PAGE <br />with smoke detectors located as required for new dwellings: <br />the smoke detectors shall be interconnected and hard wi red, <br />EXCEPTION: Detectors shall not be required to be inter- <br />connected and hard wired where the alterations, repairs~ or <br />additions do not result in the exposure of electrical wiring <br />by the removal of interior wall and ceiling finishes. <br />[Sec, 216.1.1] <br />SMOKE DETECTORS shall be installed in each sleeping room, <br />outside of each separate sleeping area in the immediate <br />vicinity of the bedrooms and on each additional story of the <br />dwelling including basements, All detectors located outside <br />sleeping rooms shall be interconnected such that the <br />actuation of one alarm will actuate these alarms in the <br />individual unit and shall provide an alarm which will be <br />audible in all sleeping areas. Smoke detectors shall be <br />110 volt with batter back-up, [Sec, 216,1] <br />FLOOR JOIST, On the revised West Elevation/Section drawing. <br />the size of the new floor joist and underfloor insulation <br />has been crossed-out. The plans submitted do not specified <br />these building materials anywhere else. therefore, <br />the minimum floor joist size shall be Doug-Fir, No, 2, 2x6 <br />and the minimum insulation shall be R-25, <br />ENERGY PATH #1 is based on R-21 wall insulation, R-25 under- <br />floor insulation, R-20 vaulted ceiling insulation, R-28 flat <br />ceiling insulation. R-15 below grade wood, concrete or <br />masonry walls. R-15 slab floor edge insulation, R-8 forced <br />air duct insulation. 0.40 U-value window class. 0,50 U-value <br />skylight class, 0.54 U-value main entry door. (with a max- <br />imum area of 24 square feet) all other exterior doors, in- <br />cluding the door between the heated dwelling and the un- <br />heated garage. 0,20 U-value. <br />EXTERIOR JOINTS around windows and door frames, between wall <br />cavities and window or door frames, between wall and <br />foundation, between wall and roof. between wall panels, at <br />penetrations or utility services through walls, floors and <br />roofs and all other openings in the exterior envelope shall <br />be sealed in a manner approved by the Building Official. <br />{E401.8,2] <br /> <br />98-07644 <br />ISSUED <br />10/05/1998 <br />04/03/1999 <br /> 3 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.