My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1522165
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1522165
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2013 3:02:20 PM
Creation date
12/13/2004 7:39:13 AM
Metadata
Fields
Template:
Permits
Permit Address
5997 SHAW CENTER PL SE
Permit City
Aumsville
Permit Number
555-98-06537
Parcel Number
082W13C 04800
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />09/01/98 11:07 PERMIT NO <br />Residential accessory struct STATUS <br />U-1 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-06537 <br />ISSUED <br />09/01/1998 <br />02/28/1999 <br /> 2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS~ Front: Left: 13 Right: 13 Rear: 13 Special~ <br /> MUST BE LOCATED IN REAR YARD <br /> <br /> 1. THIS PLAN REVIEW WAS COMPLETED BY M, JONES ON 08/31/98. <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 2.Approved for private non-commercial use only. <br /> 4. This structure is being reviewed as a NONFARM AGRICULTURAL <br /> BUILDING. <br /> The proposed use is an ARENA/BARN with 6.000 square feet. <br /> Since the square footage is greater than 2.000 square feet. <br /> the building does not meet the requirements of Sections <br /> 212.2.1 or 312,2.2. <br /> The Exception in Section 312.1 is applicable for this <br /> structure. <br /> 5. NONFARM ARIGCULTURAL BUILDING. (OSSC Appendix Chap 3) <br /> Nonfarm arigcultural building is a structure which by use or <br /> character of its occupancy is similar to a farm building but <br /> is not located on a farm, <br /> 6. E)FTERIOR WALLS & OPENINGS. (OSSC Appendix Sec 329) <br /> Except where TABLE 6-A requires greater protection, exterior <br /> walls of arigcultural buildings shall not be less than <br /> one-hour fire-resistive construction when less than 20 feet <br /> from property line. <br /> Openings in exterior walls of arigcultural buildings which <br /> are less than 20 feet from property lines shall be protected <br /> by fire assemblies having a fire-protection rating of not <br /> less than three-fourths hour. <br /> 7. MAXIMUM OCCUPANT LOAD, (OSSC Sec 1002) <br /> The maximum occupant load for this structure is 49 and less. <br /> When 50 or more occupants would be in this building, the <br /> building would be classified as an assembly area and the <br /> requirements for such use will be applicable. <br /> NOTE: AS PER THE STATMENT PROVIDED BY SUSAN WILSON, THE <br /> ARENA WILL HAVE 1-2 PEOPLE IN THE POLE BARN AT ANY <br /> ONE TIME, <br /> 8.***************** STRUCTURAL ENGINEER **~-******************* <br /> The engineer of record for this project is: <br /> MICHAEL R. SALITURO <br /> Stamp Number 08682PE <br /> 424 Cherrywood Ct. S,E. <br /> Salem. Oregon 97306 <br /> <br /> 9. TRUSS DESIGN. Roof trusses are required to be designed by <br /> an Oregon registered Engineer or Architect. For trusses <br /> manufactured by an approved fabrication plant, have the <br /> design and layout drawings available at the construction <br /> site for the framing inspeciton, All jobsite cutting or <br /> modification of the roof trusses shall be clearly shown in <br /> the engineers's design calculations and drawings, If trusses <br /> are to be built at the jobsite, submit the engineer's design <br /> and construction plans to the Marion County Building Depart- <br /> ment prior to start of construction and have the approved <br /> drawings available at the site for the framing inspection, <br /> 10. EXIT FACILITIES. (OSSC Appendix Sec 320) <br /> Exit facilities shall be as specified in Chapter 10. <br /> EXCEPTIONS: <br /> 1, The maximum distance of travel from any point in the <br /> building to an exterior exit door. horizontal exit, <br /> exit passageway or an enclosed stairway shall not exceed <br /> 300 feet. <br /> 2, One exit is required for each 15.000 square feet of <br /> floor area and fraction thereof. <br /> 3, Exit openings shall not be less than 2 feet 6 inches by <br /> 6 feet 8 inches. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.