11. <br /> <br />2. An uncoated Ilo. 4 reinforcing bar stubbed up at least 12 inches above the floor plale line and <br />tightly attached to the reinforcing bar located in thc fooling. The spliced lap of the stubbed up bar <br />to the footing bar shall be a mlnlm~lm of 12 inches. <br /> <br />EVERY SI.I~I~pING ROOM shall have at least one opanable window or exterior door approved for <br />emergency egress or rescue. The window sill height shall not be more th~n 44 inches above thc floor. The <br />mlnim~tm ~!et Clear O[~tlin~ iS 5.7 sqllare feet. Thc min~rm~m n~t clear ol~nln~ beight shall b~ 22 incbes. <br />The minimtlm net clear o~rdng width shall be 20 inghas. Exception: Grade floor windows may have a <br />minim~nl net clear opening of $ square feet. <br /> <br />THE GARAGE shall be separated from the dwelling and its atfc area by means of l/2-inch gypsum board <br />applied to the garage side of the wall. Where the separation is a floor-ceiling assembly, the structure <br />supporting the separation shall be protected by 1/2-inch gypsum board or equivalent. The door between the <br />garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches in thickness or 20- <br />m!n~e fire rated, or equivalent. <br /> <br />SMOKE DETECTORS shall be installed in each sleeping room, outside of each separate sleeping area in ~hc <br />immediate vicinity of the bedrooms and on each additional story of the dwcllinE inclodinE hascmcnts. Ail <br />detectors shall be interconnected such that the actuation of one alarm will acm~t~ all thc alarms in the <br />individual unit and shall provide an alarm which will be audible in all sleeping areas. Smoke detec~rs shall <br />be 110 volt with battey back-up. <br /> <br />SMOKE DETECTOR]POWER. Required smoke detectors shall receive their prlm~ power from the <br />building wiring when such whlng i~ served from a commercial source, and when prlm~y power is in~r- <br />rupted, shall receive power from a hailery. Smoke detectors may be halIery operated when im~all~l in <br />buildings without commercial power. <br /> <br />FIRESTOPPING shall be provided in the following locations: <br /> 1) In concealed spaces of stud walls, incl~ing furred spaces not to exceed 10 feet horizontally, <br /> and at the ceiling ~ floor level. <br /> 2) At all interconn~ions between concealed verfioal and horizontal spaces such as occur at soffits, <br /> drop or cove ceilln..o~, cto. <br /> 3) In concealed spaces between stair stringers at the top and bottom of the mn and wall cavities in <br /> ~ with the stringers; <br /> 4) .at openings arouad '*'ellis, pipas, ducts, chlm~ys and fireplaces at ce/llng and floor level, with <br /> <br />HEATING AND COOLING appliances located in a garage shall be protected from impact by automobiles. <br />Appliances that generate a glow, spark or flame capable of igniting gasoline vapors located in a garage shall <br />be installed with burners, burner ignition devices or heating elements and switohas at least 18 inches above <br />thc floor level. <br /> <br />WATER HEATERS shall be anchored or strapped to the building to resist horizontal displacement due to <br />earthquake motion. <br /> <br />TRUSS DESIGN. Roof trusses are required to be designed by an Oregon registered Engineer or Architect. <br />For trusses rnamlfactored by aa approved fabrication plant, have the design and layout drawings available at <br />the construction site for ~he ff~mlng impeefion. All job site culling or modification of the roof trusses shall <br />be clearly shown in the engineer's design calculations and drawings. <br /> <br />"APPROVED" only when this sheet is attached to plans. <br /> <br />14~tory Review 2 <br /> <br /> <br />