Laserfiche WebLink
MARION COUNTY <br />BUILDING INSPECTION <br />3150 Lancaster Dr NE Suite C <br />Salem, Oregon 97305-1398 <br /> <br />PHIl: (503) 58&5147 (8:00 AM - 4:30 PM) <br />FAX #: (503) 588-7948 <br /> <br /> Building Inspection <br />Dwelling Plan Review Notice <br /> <br />This PLAN REVIEW was completed by ~ on _~l~ll9q~ <br />This plan was reviewed under the 1996 Edition of the State of Oregon One and Two Family Dwelling Specialty Code. <br /> <br />APPROVAL of submitted plan~ is not an approval of omissions or oversights by this office or of noncompilance with <br />any applicable regulations of local government. <br /> <br />APPROVED ADDRESS NUMBERS shall be painted or affixed to the front of the building in a contrasting and <br />highly visible color, not less than six (6) inches in height for commercial nsc of four (4) ~ in height for residen- <br />tial use. The numbers shall be affixed prior to final inspection. (513) (UFC 10.301) (ORD 774) <br /> <br />A ROADSIDE MARKER shall be placed at the access point with address numbers in a contrasting and highly visible <br />color, not less than five (5) inches in height for commercial use, or three (3) inches in height for residential use in a <br />contrasting and highly visible color. <br /> <br />THE INSPECTION RECORD GREEN CARD shall be posted in a visible and readily accessible location throughout <br />construction. APPROVED CONSTRUCTION PLANS shall be kept on the site of the building or work at the time of <br />inspection. <br /> <br />WORK MAY PROCEED only at the direction of the inspector. To request an inspoction of completed work, call <br />3734427 prior to 7:00 a.m. to receive same day service. <br /> <br />A COPY OF THE APPROVED PLANS AND THIS PLAN REVIEW NOTICE SHALL BE KEPT ON <br />THE SITE OF TH~ BUILDING OR WORK AT THE TIME OF ALL INSPECTION. <br /> <br />LOT DRAINAGE. Lots shall be provided with adequate drainage and shall be graded so as to drain surface <br />water away from foundation walls. The grgde away fi~0r0, fq~tion walls shall fall a m_i_n~of 6 in. <br />within the fkr~ 10 ft~ ~re lOt Unes, walls or other phYsical banders prohibit 6" of fall within I0 feet, <br />drains or other approved means shall be provided to emu.re positive drainage <br /> <br />GROUNDING ELECTRODES. When concrete reinforcing bars are installed in concrete footings, the <br />following requirements shall be met to provide for a grounding electrode system: <br /> 1. Uncoated No. 4 reinforcing bar installed not less than 20 feet in length encased with a minimum <br /> of 2 inches of concrete. <br /> <br />1 -Story Review 1 <br /> <br /> <br />