Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: ITT SITE: <br /> <br /> DWELLING PERMIT <br />12/30/98 14:48 <br />New Single Family Dwelling <br />R-2 <br />V-N <br /> <br /> PERMIT NO 98-05857 <br /> STATUS ISSUED <br /> ISSUED 12/30/1998 <br /> TO EXPIRE 06/28/1999 <br /> PAGE 3 <br /> stairs. Ends shall be returned or shall terminate in newel <br /> posts or safety terminals, Exception: Handrails may be <br /> interrupted by a newel post at a turn, and the use of a <br /> volute turnout or starting easing shall be allowed over the <br /> lowest tread. [Sec, 215.1] <br />11. GUARDRAILS. Porches. balconies or raised floor surfaces <br /> located mere than 30 inches above the floor or grade shall <br />have guardrails not less than 36 inches in height, Required <br />guardrail shall have intern~ediate rails or ornamental <br />closures which do not allow passage of an object 4 inches <br />or more in diameter. Horizontal spacing between the <br />vertical members in required gurardrails shall be a maximum <br />of 4 inches at the nearest point between the members. <br />[Sec. 315.3; 315.4] <br />12. SMOKE DETECTORS shall be installed in each sleeping room, <br />outside of each separate sleeping area in the immediate <br />vicinity of the bedrooms and on each additional story of the <br />dwelling including basements. All detectors located outside <br />sleeping rooms shall be interconnected such that the <br />actuation of one alarm will actuate these alarms in the <br />individual unit and shall provide an alarm which will be <br />audible in all sleeping areas, Smeke detectors shall be <br />110 volt with batter back-up, [Sec. 216.1] <br />13. SMOKE DETECTOR / POWER. In new construction, the required <br />smeke detectors shall receive their primary power from the <br />building wiring when such wiring is served from a commercial <br />source, and when primary power is interrupted, shall receive <br />power from a battery. Wiring shall be permanent and not <br />switched. Smoke detectors shall be permitted to bo battery <br />operated when installed in existing buildings without <br />commercial power or in buildings which undergo alterations, <br />repairs or additions regulated by Section 316,11 <br />[Sec, 316.2] <br />14. ENERGY PATH #9 is based on a minimum wall component for <br />Path 9 shall be an average solid log or timber wall thick- <br />ness of 2,5 inches (all framed walls shall bo R-21). R-30 <br />underfloor insulation. R-28 vaulted ceiling insulation, <br />R-49 flat ceiling insulation. R-15 below grade wood. <br />concrete, or masonry walls, R-15 slab floor edge insulation. <br />R-8 forced air duct insulation. 0,40 U-value window class. <br />0.50 U-value skylight class. 0,54 U-value all exterior doors <br /> <br /> <br />