Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: DT SITE: <br /> <br /> DWELLING PEPJ4IT <br />12/20/98 14:48 PERMIT NO <br />New Single Family Dwelling STATUS <br />R-2 ISSUED <br />V-N TO EXPIRE <br /> P~E <br /> <br />98-05857 <br />ISSUED <br />12/30/1998 <br />06/28/1999 <br />2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 5 Right: 5 Rear: 15 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> A1-FENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> mey obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br /> 2. THIS PLAN REVIEW was completed by J TRUSSELL ON 12-28-98. <br /> This plan was reviewed under the 1996 Edition of the State <br /> of Oregon One and Two Family Dwelling Specialty Code. <br /> 3, Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. GROUNDING ELECTRODES. When concrete reinforcing bars are <br /> installed in concrete footings, the following requirements <br /> shall be met to provide for a grounding electrode system: <br /> 1, Uncoated No. 4 reinforcing bar installed not less <br /> 20 feet in length encased with a minimum of 2 inches of <br /> concrete, <br /> 2. An uncoated No. 4 reinforcing bar stubbed up at least <br /> 12 inches above the floor plate line and tightly attached to <br /> the reinforcing bar located in the footing, The spliced lap <br /> of the staubbed up bar to the footing shall be a minimum of <br /> 12 inches. (See Section 4108.1.2) [Sec. 403,4] <br /> 5. CUT SLOPES. Slopes for permanent fills and cut slopes for <br /> permanent excavasions shall not be steeper than two units <br /> norizontal to one unit vertical. A steeper cut slope may be <br /> extablished only after presentation of a soil investigation <br /> report acceptable to the Building Official. [Sec. 401.5] <br /> 6. LOT DPJkINAGE. Lots shall be provided with adequate drainage <br /> and shall be graded so as to drain surface water away from <br /> foundation walls. The grade away from foundation walls shall <br /> fall a minimum of 6 inches within the first 10 feet, Where <br /> lot lines, walls or other physical barriers prohibit <br /> 6 inches of fall within 10 feet, drains or other approved <br /> means shall be provided to ensure positive drainage. <br /> [Sec. 401.3] <br />7. ENG. This structure uses an Engineered Design to meet the <br /> lateral wall bracing requirements of the code. Insure that <br /> all detailed construction requirements shown on the plans <br /> are followed. <br />8. EVERY SLEEPING ROOM shall have at least one openable window <br /> or exterior door approved for emergency egress or rescue. <br /> The window sill height shall not be mere than ~ inches <br /> above the floor. The minimum net clear opening is 5.7 square <br /> feet. The minimum net clear opening height shall be 22 <br /> inches. The minimum net clear opening width shall be 20 <br /> inches. Exception: Grade floor windows may have a minimum <br /> net clear opening of 5 square feet. [Sec. 210.2. 210.2.1] <br />9. STAIRWAYS shall not be less than 36 inches in clear width at <br /> all points between the handrail height and the required <br /> minimum headroom of 6 feet 8 inches. Minimum width from the <br /> handrail down is 22 inches with one handrail. 28 inches with <br /> two. The minimum required stair tread width is 9 inches, <br /> The maximum stair rise is 8 inches, When risers are closed. <br /> all treads less than 10 inches shall have a uniform nosing <br /> betweem 3/4 inches and 1 1/4 inches, The greatest riser <br /> height/tread depth shall not exced th smallest by mere than <br /> 3/8 inch. [Sec. 214.1; 314.2: 214.2.1: 314,3] <br />10. HANDEAILS having a minimum and maximum height of 20 inches <br /> and 28 inches, respectively, shall be provided on at least <br /> one side of stairways of more than three risers. All re- <br /> quired handrails shall be continuous the full length of the <br /> <br /> <br />