Laserfiche WebLink
This plan was reviewed under the 1996 Edition of the State of Oregon One and <br />Two Family Dwelling Specialty Code. <br /> <br />CONDITIONS REQUIRED: <br /> <br />THIS PLAN REVIEW was completed.by TOM LARSEN ENTERPRISES <br />PLANS EXAMINER ~'~..~..~f~ ~""~'~,bl~$~,~ on_~z/~/19~~ <br /> <br />ACTVITY NO. 98-04924 <br />TLE NO. 98-1051 <br /> <br />CONDITIONS REQUIRED: <br /> <br />This plan was reviewed under the 1996 Edition of the State of Oregon One and Two Family <br />Dwelling Specialty Code. <br /> <br />APPROVAL of submitted plans is not an approval of omissions or oversights by this office <br />or of noncompliance wit~ any applicable regulations of local government. <br /> <br />]. LOT DRAINAGE. Lots shall be provided with adequate drainage and shall be graded so as <br />to drain surface water away from foundation walls. The grade away from foundation walls shall <br />fall a minimum of 6 in. within the first 10 ft. Where lot lines, walls or other physical barriers <br />prohibit 6" of fall within 10 feet, drains or other appre,~ed means shall be pro'~idad to ensure <br />positive drainage. [ <br />1. BIDC0047 FOUNDATION SIZE. Footing and Foundation size minimum requirements: <br />[Table 403.2] <br />Floors supported Footing size Stem Wall Thickness <br /> 1 I 6" x '12" 6" <br /> 2 7"x 15" 8" <br /> 3 8" x 18" 10" <br />".).BIDC0072 CRAWL HOLE. Provide an access crawl hole to the underfloor space. The <br />minimum size opening required is 18 inches by 24 inches. [Sec. 409.2] <br />3.BIDC00139 SAFETY GLAZING/AT DOOR. The following shall be considered specific <br />hazardous locations for the purposes of glazing. <br /> 1~ Glazing, in an individual fixed or operable panel adjacent to a door where the nearest <br />vertical edge is within a 24-inch arc of the door in a closed position and whose bottom edge is <br />less than 60 inches above the floor or walking surface. Exception: Safety glazing is not required <br />when there is an intervening wall or other permanent barrier between the door and the glazing <br />4.BIDC00175 SMOKE DETECTORS shall be installed in each sleeping room, outside of each <br />separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of <br />the dweiting including basern,=~t~: Ail detectors shall be interconnected such that the actuation <br />of one alarm will actuate all the alarms in the individual unit and sha~ provide an alarm which will <br />be audible in all sleeping areas. [Sec. 316. ~ ] Smoke detectors shall be 110v with battery back- <br />up. [Sec. 316.2] <br /> <br /> <br />