Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lallea~ter Dr. N.E. · Suite C · S~tem, Oregon 97305-1398 <br />Office Houm: 8:00.4:30 * Phone: (503) 588-6147 · 24.HR Inepeotion Line: (503) 373-4427 <br /> <br /> ~UILDZN~ PERHZT <br />DATE/TItlE : ~2/26/98 14;25 <br />TYPE = Resident. addition/alteration <br />OCCUPANCY = R~3 <br />CON~T.TYPE :~V-N <br />UGB= StTE~ FD <br /> <br /> PAGE <br /> ,~one side of stairwags of ~ore than thr'ee r'isev's. All re- <br /> -quired handrails shall be continuous the full ~ength of the <br /> stairs. Ends shall be-returned or shall terminate in newel <br /> prints or safe~¥ terminals. Exception: Handrails ~a~ be <br /> znter?upted by a ne~ez post at a turn, and the use o~ a <br /> volute turnout er starting easing shall be allo~ed ove~~ the <br /> lowest t~-ead. [Sec. <br /> SMO~E DETECTORS / ~L.TERATIONS. ~hen alterations, ?eoai~"s <br /> additions are ~ade to an existing dwelling~ the &nti~e <br /> building shall be provided ~ith s~oke detectors located as <br /> require~ for new d~ellings. The s~oke detectors are no~ <br /> required to be interconnected unless ~r~her ?eeodeling con- <br /> siderations r~quire retrieval O~ the appropriate wall and <br /> ceiling coverz~gs to facilitate interconnecting airing. <br /> [Section <br />13.~SHOKE I>ETECTORS shall he ~nstalled in each sleepin~ <br /> outside of each separ'ate sleeping area i~ the i~e~iate <br /> vicinity of the bedrooms and on ~ach additional story of the <br /> daelIing including basements. Ail detecto~-s shall be inter- <br /> co~nected s~xch that the actuation of one ala?~ aill actuate <br /> all the alarms in the individual unit and shall ~?ovide an <br /> alar~ ~h~ch ~ill be audible in all sleepinq areas. <br /> ESection 31&.l] S~oke detectors shall be 110 volt ~ith <br /> battery back-up~ ESec, <br /> COH~OSTION AIR. Fuei burning equipment shall be provided <br /> ~:ith ~ sufficient supply of air fo? fuei combustion, draft <br /> hood dilution and ventilation of the sprace in ~hich the <br /> eguip~ent is installed. Plans do not shoa hoa combustion <br /> ait is going to be provided~ See the Manufacturer's <br /> ~.nstallation instru~tious and Chapter 20 of the State of <br /> Oregon ODe and TaD Family O~elling Specialty Code for <br /> gui~anl:e. [Sec. 20~1~1] <br /> DOES THIS APPLY TO YOU~ FURNACE??7 <br /> EHERGY PATH ~l is based on R-21 ~all insulation, R-2d under- <br /> flo~r insulation~ R-~ vaulted ceilin~ insulation, R-SB flat <br /> ce~.ling insulation, R-21 .base~enet ~alls, R-15 slab floor <br /> edge insulation~ R-8 forced air' duct insulation, <br /> 0.4~ U-value aind~)~ class, 0~50 U-value skyligh~ cl~ass, <br /> 0.54 U-value ~ain entry door~ (with a ~axi~u~ area of L~4 <br /> s~uare feet) all other exterior doors, including the door <br /> b&taeen the heated d~elling and the unheated garage, <br /> U-value. <br /> THE ROOM SHOWN IH THE BASEMENT IS BEING REVIEWED AS ~ <br /> ~EDRO~H ~S IT CONTAINS ~ CLOSET. ~S ~ BEDROOM IT HEEDS TO <br /> VE AH EGRESS gIHDOW <aS DESCRIDED ABOVE) OR ~ DOOR DIRECTLY <br /> I'0 THE OUTSI~E. IF THIS IS JHOT POSSIBLE, THE CLOSET WILL <br /> HEED TO ~E COMPLETLY REMOVED. <br /> THE WALLS IN THE BASEMENT ~PPEAR TO ~E STEEL STUDS. DO HOT U <br /> SE STEEL STUDS FOR LOAD ~EARING WALLS. <br /> ~£HE FLOOR JOISTS UHDER THE ga4.LS OH THE SIDES OF THE HEW <br /> DORMER HEED ¥0 ~E DOUaLED UP TO SUPPORT THE gALL LOAD. <br /> THE RA~TER TIES ~HOW~ INSTALLED IN THE aTTIC AREA NEE~ TO BE <br /> AT LEAST 2X6 COHST~IJCTIOH WI~H AT L~aST & l&d NAILS IH EACH <br /> EHD. HAILS ~AY R~OU~RE ~ILOT HOLES TO KEEP FROM SPLITT!HG <br /> THE <br /> NAXINHM HEIGH 19F RAFTER TIES OFF ~F THE FIHISHED FLOOR IS <br /> 7' 9". <br /> <br />PERHIT NO = 9B-O~Bll <br />STATUS : ISSUED <br />ISSUED : B2/26/199B <br />TO EXPIRE : 08/25/1998 <br /> <br /> <br />