Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br /> <br /> 3150 Lancaster Dr. N.E. · Suite C · Salem, Oregon g7305-1398 <br />Office Hourm: 8:00-4:30 · Phone: (~03) 588-5147 · 24-HR Inspection Line: (503) 373-4427 <br /> <br /> ~JILDIN~ PERHIT <br />DATE/TIHE B2/26/~8 14=25 <br />TYPE Resident. addition/alteratJoh <br />OCCUPAHCY <br />CONST TYPE : V-N <br />UGB: BITE: FB <br /> <br />PERHIT HO : ?S-~11 <br />STATUS ~SSUEI) <br />ISSUE1) ~ 82/26/i~8 <br />TO EXPIRE : ~8/25/1978 <br />PN;E 2 <br /> <br />PLAN REVIEW COMMENI'S AND CONDITIDNS <br /> <br />REQll..RED SETBACKS: Front: Left: Right: Rear: Spec. iai: <br /> <br /> THIS PLAN REVIEW WAS COMPLETED BY DWALTERS OH 2/25/98. <br /> 1996 CODE. <br /> Approval of submitted plams is not an approval ~f omissions <br /> o~ oversights h~ this bffice or of noncompliance with 'any <br /> aPPlicable regulations of local qovernmen~. <br /> S~NCE THE FLOOR SYSTEM IN T~ Lt~ING ROOM WAS REPLACED, IT <br /> NEEDS TO BE BROOGNT UP TO ~ODE. THE BEAM IS OVERSPAN. <br /> EITHER REPLACE THE BEAM WITH A STRONGER BEAM~ SUCH AS A ~l/S <br /> X 13 1/2 GLU-LAM OR REDUC~ THE SPAH TO NO MORE THAN 12 FEET <br /> BY ~NSTALLING A NEW POST (~i A PIER BLOCK (OR EQUIVALENT). <br /> IF ,NE FLOOR SYSTEM OVER THE OTHER 6X12 WAS AESO REPLACED, <br /> THE SANE COMMENTS APPLY. <br /> IT IS VERY DIFFICULT TO TELL FROM THE PLANS WHA1 IS NEW AND <br /> WHAT IS EXISTING IN TH)~ STRUCTURE. THE INSPECTOR SHALL <br /> FIELD VERIFY WHAT IS ~EW <br /> A~Y NEW WORK THAT IS NOT COVERED BY THIS REVIEW SHALL <br /> REQUIRE ADDITIONAL PERMITS. <br />5~' FHE ATTIC AREA SHALL BE CONSIDERED TWO BEDROOMS AS THEY <br /> CONTAIN CLOSETS. EACH BEDROOM SMALL HAVE AW EGRESS WINDOW. <br /> (SEE COMMENT ON BEDROOM ~IHDOWS) <br /> THE NEW WALLS FOR THE DORMER SHALL ~X4 CONSTRUCTION. R-21 IS <br /> REQUIRED IN,WALLS. R-~t REQUIRES A 5 1/2" DEEP STUD BAY. <br /> EITHER FUR,.WALLS OUT TO ACCEPT R-~I OR INSTALL R-l§ IN THE S <br /> TUD BAY AND PLACE FOAM, MINIMUM R-~.5, OVER THE ENTIRE WALL <br /> SURFACE. <br /> ACCEPTABILITY. Thais plan review covers the addition to and/ <br /> or alteration of an existing structure. This ~eview is not <br /> intended to prohibit the bullUin~ inspector fFom requesting <br /> an evaluation of the acceptability of existing structural <br /> members that may appear to be unsafe. Existing construction <br /> no~ specifically detailed in the sub~i~ed plans and struc- <br /> tura~ calculations is beyond the scope ~f this review. <br /> IT AFPEARS FROM THE PLANS TMAN NEW WINDOWS WERE INSI'ALLED IN <br /> THE SAME OPENINGS AS THE OLD WINDOWS. IF STRUCTURAL CHANGES <br /> WERE REQUIRED TO INSTALL THE WINDOWS--I.E,, NEW HEADERS-- <br /> APPLY FOR AN ADDENDUM BY SHOWING WHERE THOSE WINDOWS ARE AND <br /> CONSTRUCTION OF THE NEW HEADERS. <br /> EVERY SLEEPING ROOM shatl have at least one openable ~indow <br /> or exterior door approved'for~emergency egress or rescue. <br /> The wi~)d~w sill height shall not be more ~han 44 inches <br /> above the floor. The minimum net cte~r openinq is 5.7~square <br /> feet. The minimum net clear opening height s~all <br /> inches. The minimum net clear opening width shall be 20 <br /> incheS. Exception. Grade floo~ winUows may have a minimum <br /> ne~ clear opening of 5 square (eet. [Sec. 31~.2, 3!0.2.1] <br /> STAIRWAYS shall not be less than 3~ inches in clear.width at <br /> all points between the handrail height?nd the required <br /> minimum headroom of 6 feet S inches, minimum width from the <br /> handrail down is 32 inches with .one handrail, 20 inches with <br /> two. Theminimum required stair tre~d width is ? inches. <br /> The ma~iw~lm stair F~se i~ 8 incheS. When risers aFe closed~ <br /> all treads less than 10 inches shall h~ve ~ uniform nosing <br /> betweem 3/4 inches and I 1/4 inches.~ The greatest' riser <br /> height/tread depth sh~ll not ~xc~d th smallest by mo)~e than <br /> 3/8 inch. [Sec. 314~I; 3t. 4.2~ 314~2,~],; 314.3] <br /> TH~S APPLIES T8 THE NEW STAIRS GOING"TO ~HE ATTIC BEDROOMS, <br /> HANN:;AILS having m miniM~l~ ~nd msxlm~ height of ~8 inches <br /> and ~8 inches, resoectively, shall b~ nrovided o~ ~t least <br /> <br /> <br />