My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
DWELL - 1502512
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
DWELL - 1502512
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2013 12:03:11 PM
Creation date
10/12/2004 7:22:54 AM
Metadata
Fields
Template:
Permits
Permit Address
9832 JORDAN ST SE
Permit City
Aumsville
Permit Number
555-98-00433
Parcel Number
081W18 00500
Permit Type
DWELL
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TO/v LARSEN ENTERPRISES <br /> <br />~ 3896 Beverly Avenue NE <br />· Suite 22A <br /> Salem, Oregon 97305 <br /> 503-362-0920 <br /> <br />THIS PLAN REVIEW was completed by T.O~OM LARSEN ENTERPRISES <br /> <br />PLANS EXAMINER: on./ <br />ACTIVITY NO. 98-00433 <br /> <br />TLE NO. 98-1022 <br /> <br />CONDITIONS REQUIRED: <br /> <br />1. LOT DRAINAGE. Lots shall be provided with adequate drainage and shall be graded so as to <br />drain surface water away from foundation walls. The grade away from foundation walls shall fall a <br />minimum of 6 in. witch the flint 10 ft. Where lot lines, walls or other physical barriers pmhibi~6{~[. <br />fall within 10 feet, ~r~ns4?f~tfler approved means shall be provided to ensure positive drainage. <br />[Sec. 401.3] ',. ~ <br /> <br />I. CONCRETE SPECIFICATIONS· Basement walls and foundations not expos~f~ to the weather, <br />basement slabs and interior slabs on grade, e)roept garage floor and steps e~po,s,e,d t9 ~the weather <br />shall have a minimum compressive strength of 2500 psi. Basement walls, fo't~}~l:~iatton'Wdits, exterior <br />walls, and other vedical concrete work exposed to the weather, porches, carport slabs, and steps <br />exposed to the weather, and garage floor slabs shall have a minimum specified compressive <br />strength of 3000. Concrete shall be air entrained. Total air content (percent~by volume of <br />concrete) shall not be less than 5 percent or more than 7 percent. [Sec. 402.2,, Table 402,.2] <br />3. REMOVAL OF DEBRIS :l'he underlloor area shall be cleaned of all vegetation and organic <br />materials and construction debris. [Sec. 409.3] <br /> <br />4. THE TJI FLOOR joist system shall be installed in accordance with its listing and the <br />manufacturer's installation instructions. Please have the installation instructions available during <br />the framing inspection. <br /> <br />5. BP,ABP.:'This'structure uses a combination of Brace Wall Panels (BP) and Alternate Braced <br />Wall Panels (ABP) to meet the code requirements for lateral wall bracing. Insure that all BP's and <br />ABP's are located as indicated on the plans and constructed as shown <br /> <br />6. TRUSS DESIGN. Roof trusses are required to be designed by an Oregon registered Engineer <br />or Architect. For trusses manufactured by an approved fabrication plant, have the design and <br />layout drawings available at the construction site for the framing inspection. All job site cutting or <br />modification of the roof trusses shall be cleady shown in the engineer's design calculations and <br />drawings. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.