Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION' <br /> <br /> 3150 Lancaster Dr. H.E.', Suite C · Salem, Oregon 97305-1398 <br />Office Houri: 8:00-4:30 · Phone: (503) 588.5147 * 24-HR Ir~pectlon Line: (503) 373-4427 <br /> <br /> BUILDII~ PERMIT <br />DATE/TIHE : 02/25/98 ~8:31 PERHIT HO : 98-0~845 <br />TYPE = Hew CoMMercial STATUS : ISSUED <br />OCCUPAHCY : B ISSUED : ~2/25/1778 <br />COHST TYPE = V-N TO EXPZRE : ~8/24/1778 <br />U(;B: AH SITE: PA~£ 2 <br /> <br />REQUIRED SETBACKS: <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br /> Front: . L;eft: Right: Rear: <br /> 8 SE]' BACKS FER CITY/AUMSVILL~ <br /> <br /> 1. THIS PLAN REVIEW WAS COHPLETED ? DWALTERS ON 2/25/98. <br /> SEE THE ATTACHED WORDPERFECT ~06UMENT ~800845 LABELED "PLAN <br /> REVIEW NOTICE" FOR MORE CONDITIONS. <br /> 1~76 CODE. <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> ~. THE FIRE SPR1RKLER PLAN REVIEW WAS COMPLETED BY M. JONES ON <br /> 02/11/98. <br /> 4. This is a Fire and Life Safety Plan Review covering the <br /> installation of a hydrauticall,y designed automatic fire <br /> sprinkler system throughout the above indicated building. <br /> 5. As this installation is required b~ the l~?& Edition of the <br /> Oregon Structural Specialty Code ( ~4 UBC), the installation <br /> is to be in co~pliance the OSSC Chapter ? and UBC Standard <br /> ~-1 as amended by the State of Qr'egon. <br /> 6. This review does not cover regulations for insurance credits <br /> 7o i'he sprinkler system submitted :i.s based on a LIGHT HAZARD <br /> OCCUPANCY where the quantity and/or combustibility of <br /> contents is low~ and fires with relatively low rates of heat <br /> release are expected. <br /> The use of this building is classified as an office. <br /> 8. As ~ pro~e?~n is d~pendent u~o~'the water supply, a <br /> connexion or ~nz.~ approval is the reg~.~ireMent that the <br /> avai~.aoie water supply shall not be less than the Minimum <br /> acceptable lis~ed in NFPA Standard 1~. <br /> ~. This review is liM£ted to the f~re and Life Safety requzre- <br /> Merits and does not cover or imply acceptance for the <br /> additional dead and live loads placed upon the structural <br /> eleme?s of the building. (NFPA 17 Sec 2-~.1.3) <br />10. SPRiNkLER SYSlEM MONITORING & ALARMS. (0S$C Sec ~04.~) <br /> All valves controlling the water su@pl¥ for a~toMatic <br /> sprinkler systems and water-flow switches on all sprinkler <br /> syste~ shall be electrically Monitored where the number of <br /> sprinklers are one hundred or More. <br /> Valve Monitoring and water-flow alarm and trouble signals <br /> shall be distinBtly different and shall be automatically <br /> transmitted to an approved central station, remote station <br /> or' proprietary Monitoring station as defined ~y national <br /> standards, or, when approved by the buuilding official with <br /> conc;~r'rence of the chief of thb fire department, sound am <br /> ~gdible ~ignal at a constantly attended location. <br />1~. ~PRINKLEK SYSTEM MONITORING & ALARMS. cont'd. <br /> An a~proved audible sprinkler flow alarm shall be provided <br /> on the exterior of the building in an approved location. An <br /> aprnved audible sprinkler flow alarm to alert the occupants <br /> shall be provided i~ the inter'lot of the building in a <br /> norMall¥ occu~:~ied location. Actuation of the alarm shall be <br /> as set Torth in U~B.C. Stmndar~ 9-1. <br />12. EXTERIOR ROOFS f)R CANOPIES. (NFPA SEC 4-1~.7.2) <br /> SrinWlers shall be installed under' exterior combustible <br /> roofs or canopies exceeding 4 feet zn width. <br /> Thc plans submitted do not show this 8 foot wide by 22 foot <br /> long exterior canopy. As per ti)e structural plans, this <br /> canop~ is constructed of combustible Materials. <br /> PROVIDE SPRINKLER COVERAGE AS PER THIS SECTION. <br />17. DRAINAGE- (N:PA 1~ Sec 4-14.3) <br /> <br />SpeCial: <br /> <br /> <br />