My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1502483
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1502483
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2013 12:08:20 PM
Creation date
10/12/2004 7:22:35 AM
Metadata
Fields
Template:
Permits
Permit Address
945 OLNEY ST
Permit City
AUMSVILLE
Permit Number
555-98-00845
Parcel Number
082W25A 00500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
P~e3 <br /> <br />15. <br /> <br />16. <br /> <br />17. <br /> <br />18. <br /> <br />19. <br /> <br />20. <br /> <br />21. <br /> <br />CC <br /> <br />If handrails are not continuous, they shall extend at least 12 inches beyond the top riser and at <br />least 12 inches plus the width of one freed beyond the botlom riser. At the top, the extension shall <br />be parallel with the floor or ground surface. At the bottom, the handrail shall continue to slope for <br />a distance of the width ofune tread from the bottom riser. The remainder of the extension shall be <br />horizontal. Handra'fl extensions shall comply with ADAAG figure 19. <br />The clear space between the handrails and the wall shall be 1-1/2 inches. <br />Gripping surfaces shall be uninterrupted by newel posts, other construction elements or <br />obstructions. <br />Top of handr~d gripping surface shall be mounted between 34 inches and 38 inches above stair - <br />nosing. <br />Ends of handrails shall be returned to the floor, wall or post. <br />Hendrails shall not rotate within their fittings. (1109.8.6) <br /> <br />Stair nosing shall be flush and rounded to a radius of ~ inch maximum. Risers shall be sloped, or the <br />undemide of the nosing shall have an angle of not less than 60 degrees fi.om the horizontal. Nosing shall <br />project no more than 1-1/2 inches. (1109.8.3) <br /> <br />Stair nosing and treads shall have a slip resistance surface (1109.8.4) <br /> <br />Exposed stairways and their approaches shall be constructed to prevent the accumulation of water on <br />walking surfaces. (1109.8.5) <br /> <br />Toilet room floors shall have a smooth, hard, nonabsorbent, surface such as portland cement, concrete, <br />ceramic tile or other approved mater/al which extends upward onto the walls at least 5 inches. (807.1.1) <br /> <br />Walls within 2 feet of the from and sides of urinals and water closets shall have a smooth, hard, <br />nonabsorbent surface such as portland cement, concrete, ceramic tile or other smooth, hard nonabsorbent <br />surface to a height of 4 feet, and except for stmetoral elements, the materials used in such walls shall be of <br />a type which is not adversely affected by moisture. (807.1.2) EXCEPTIONS: 1. Dwelling units and <br />guest rooms. 2. Toilet rooms which are not accessible to the public and which have not more than one <br />water closet. <br /> <br />Seismic bracing is required for dropped ceiling areas. <br /> <br />The floor system has been changed from TII 15's to TIIfPRO 150's as per ~ fax fi.om Rock Shetter on <br />2/24/98. <br /> <br />Donald K. Miller, Deputy State Fire Marshal <br />Office of State Fire Marshal, 4760 Portland Rd NE, Salem, OR 97305 (503) 378-3473 X250 FAX <br />373-1825 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.