Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />06/26/98 15:09 PERMIT NO 98-02293 <br />Commercial addition/alteration STATUS ISSUED <br />S~5 ISSUED 06/26/i998 <br />V-N TO EXPIRE 12/23/1998 <br /> PAGE 2 <br /> <br /> building or portion thereof shall conform to the <br /> requirements of this section, <br /> EXCEPTION: Stairs and ladders used only to attend equipment <br /> or window wells are exempt from the requirements <br /> of this section, <br /> 12, STAIRWAY WIDTH. (OSSC Sec 1006.2) <br /> Stairways serving an occupant load of 49 or less shall not <br /> be less than 26 inches in width. <br /> Handrails may project into the required width a distance of <br /> 2 1/2 inches from each side of a stairway, <br /> Stringers and other projections such as trim and similar <br /> decorative features may project into the required width <br /> I 1/2 inches on each side. <br /> 13. PLANS NOTE %HIP LADDER". <br /> Ladders are use~ only to at~end equipment or window wells. <br /> therefore, the 'ship ladder is not approved as a legal exit <br /> way from the second floor storage areas. <br /> Reference OSSC Section 1006,1. Exceptiom <br /> The "ship ladder" is acceptable for access to attic areas or <br /> similar spaces which are considered non-habitable space. <br /> PROVIDE CODE COMPLYING STAIRWAY TO SECOND FLOOR STORAGE AREA <br /> OR SECOND FLOOR WILL BE CLASSIFIED AS NON-HABITABLE SPACE IF <br /> "SHIP LADDER" REMAINS IN PLACE. <br /> 14. ENGINEER OF RECORD. <br /> According to the Oregon State Board of Examiners for <br /> Engineering and Land Surveying 1996 Reglsty. <br /> Walter ~, Sherman is registered as a professional engineer, <br /> stamp number 13872PE. <br /> As per ORS 672.020. drawings and plans prepared by an Oregon <br /> registered engineer shall be stamped and signed by the <br /> registrant. <br /> The plans submitted w~re not stamped and signed by Walter <br /> Sherman who prepared the plans· <br /> 15. STRUCTURAL OBSERVATION. (OSSC Sec 1702) <br /> Structural observation is required by this office. <br /> The owner shall employ the engineer or architect responsible <br /> for the structural design, or another engineer or architect <br /> designated by the engineer or architect responsible for the <br /> structural design, to perform structural observation as <br /> defined in Section 220. Observed deficiencies shall be <br /> reported in writing to the owner's representative, special <br /> inspector, contractor and the building official. <br /> 16. STRUCTURAL OBSERVATION. cont'd. <br /> The structural observer shall submit to the building officia <br /> 1 a written statement that the site vislts have been made <br /> and identifying any reported deficiencies which, to the best <br /> of the structural observer's knowledge, have not been <br /> resolved. <br /> PRIOR TO FINAL APPROVAL, THE WRITTEN STRUCTURAL OBSERVATION <br /> SRALL BE SUBMI~ED TO THIS OFFICE AND SHALL BE SEALED WITH <br /> THE ENGINEER'S STAMP AND SIGNATURE. <br /> 17. STRUCTURAL OBSERVATION, (OSSC Sec 220) <br /> Structural observation means the visual observation of the <br /> structural system, for general conformance to the approved <br /> plans and specifications, at significant construction stages <br /> and at completion of the structural system, <br /> Structural observation does not include or waive the <br /> responsibility for the inspections required by Section 108. <br /> 1701 or other sections of this code. <br /> 18. CONTACT PERSONS: <br /> ~w9. Donald K. Miller. Deputy State Fire Marshal <br /> State of Oregon Fire Marshal <br /> 4760 Portland Rd, NE <br /> Salem, Oregon 97205 <br /> P~. (502) 378-4917 <br /> ~FAX: (502) 373-1825 <br /> 20. Dick Johnson. Fire Marshal <br /> Aurora RFPO (Marion/Clackamas) <br /> PO Box 100 <br /> Aurora. OR 97002 <br />v~21 PH: (502) 678-1282 · Ed Graham <br /> <br /> <br />