My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1501262
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1501262
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2013 1:14:39 PM
Creation date
10/12/2004 7:07:35 AM
Metadata
Fields
Template:
Permits
Permit Address
23055 AIRPORT RD NE
Permit City
Aurora
Permit Number
555-98-02293
Parcel Number
041W02A 00600
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />06/26/98 15:09 PERMIT NO <br />Commercial addition/alteration STATUS <br />S-5 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />98-02293 <br />ISSUED <br />06/26/1998 <br />12/23/1998 <br /> 2 <br /> <br />REQUIRED SETBACKS: Front: <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br /> Left: Right: Rear: <br /> <br />Special: <br /> <br /> 1. THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 05/12/98, <br /> 2. Approval of submitted plans ls not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 3. Local Fire D~strlcts may have additional requirements that <br /> affect this project. You are advised to contact the Fire <br /> District before you proceed. <br /> 4, This is a Plan Review covering the construction of the <br /> additions and alterations to the above indicated building, <br /> The plans have been checked for compliance with the <br /> provisions of the Oregon State Structural Specialty Code <br /> ('94 UBC) 1996 Edition. <br /> 5. This review is not intended to prohibit the building <br /> inspector from requesting an evaluation of the <br /> acceptability of existlng structural members that may <br /> appear to be unsafe. Existing construction not <br /> specifically detailed in the plans and structural <br /> calculations is beyond the scope of this review. <br /> 6, STAIRWAY WIDTH. (OSSC Sec 1006.2) <br /> Stairways serving an occupant load of 49 or less shall not <br /> be less than 36 inches in width. <br /> Handrails may project into the required width a distance of <br /> 3-1/2 inches from each side of a stairway, Stringers and <br /> other projections such as trim and similar decorative featur <br /> es may project into the required width 1-1/2 inches on each <br /> side, <br /> 7. FLOOR DESIGN. (OSSC Sec 1604) <br /> Floors shall be designed for the unit loads set forth in <br /> TABLE 16-A. These loads shall be taken as the minimum live <br /> leads in pounds per square foot of horizontal projection to <br /> be used in the design of buildings for the occupancies <br /> listed, and loads at least equal shall be assumed for uses <br /> not listed in this section but which create or accommodate <br /> s~milar loadings. <br /> 8. LIVE LOADS POSTED. (OSSC Sec 1604.5) <br /> The live loads for which each floor or part thereof of a <br /> commercial or industrial building is or has been designed <br /> shall have such designed live loads conspicuously posted by <br /> the owner in that part of each story in which they apply. <br /> using durable metal signs, and it shall be unlawful to <br /> remove or deface such notices. The occupant of the building <br /> shall be responsible for keeping the actual load below the <br /> allowable limits, <br />9. LIVE LOAD POSTED, cont'd. <br /> <br /> * THE MAXIMUM LIVE LOAD FOR THE STORAGE AREA ON THE * <br /> * SECOND FLOOR IS 25 PSF. * <br /> <br /> *THERE SHALL BE NO LIVE LOAD ON THE CANTILEVER FLOOR JOIST.* <br /> <br />10. DESIGNERS RESPONSIBILITY. <br /> The plans submitted do not clearly show all the required <br /> framing details. It is the designer's responsibility to <br /> size all structural members and fasteners for the <br /> ~pro~riate loads and have them shown on the plans. <br /> e plans submitted have the following deficiencies: <br /> 1. No dimensions shown, <br /> 2. No cross sections. <br /> 3. Two different floor joist sizes. <br /> 4, Ship ladder specified, but stairway shown, <br /> 5. Detail of floor joist cantilever framing. <br /> 6. Detail of bottom of posts (footings. connections, etc). <br />11, STAIRWAYS, (OSSC Sec 1006.1) <br /> Every stairway having two or more risers serving any <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.