DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />09/16/99 16:44 <br />Resident. addition/alteration <br />R-3 <br />V-N <br /> <br />12. <br /> <br />13. <br /> <br />18. <br /> <br />16. <br /> <br />17. <br /> <br />PERMIT NO <br />STATUS <br />ISSUED <br />TO EXPIRE <br />PAGE <br />sidered a specific hazardous location for the purposes of <br />glazing. Glazing in an individual fixed or operable pane <br />that meets all of the following conditions: <br />1. Exposed area of an individual pane greater than 9 sq. ft <br />2. Bottom edge less than 18 inches above the floor. <br />2. Top edge greater than 36 inches above the floor. <br /> <br />SAFETY GLAZING / LARGE PANE.(Continued, see above conditioni <br />~. One or more walking surfaces within 36 inches horizon- <br />tally of the glazing. Exception: In lieu of safety glazing <br />this specific glazed panel may be protected with a pro- <br />tective bar installed on the accessble side(s) of the <br />glazing 36 inches (plus or minus 2 inches) above the floor. <br />The bar shall be capable of withstanding a horizontal load <br />of 50 pounds per linear foot without contacting the glass <br />and be a minimum of I 1/2 inches in height. <br /> <br />SMOKE DETECTORS / ALTERATIONS. When alterations, repairs or <br />additions requiring a permit occur, or when sleeping rooms <br />are added or created, the entire building shall be provided <br />with smoke detectors located as required for new dwellings: <br />the smoke detectors shall be interconnected and hard wired, <br />EXCEPTION: Detectors shall not be required to be inter- <br />connected and hard wired where the alterations, repairs, or <br />additions do not result in the exposure of electrical wiring <br />by the removal of interior wall and ceiling finishes, <br />[Sec. 316.1,1] <br /> <br />SMOKE DETECTORS shall be installed in each sleeping room, <br />outside of each separate sleeping area in the immediate <br />vicinity of the bedrooms and on each additional story of the <br />dwelling including basements. All detectors located outside <br />sleeping rooms shall be interconnected such that the <br />actuation of one alarm will actuate these alarms in the <br />individual unit and shall provide an alarm which will be <br />audible in all sleeping areas. Smoke detectors shall be <br />110 volt with batter back-up. [Sec. 316.1] <br /> <br />WATER HEATERS shall be anchored or strapped to the building <br />to resist horizontal displacement due to edrthquake motion. <br />[Section 510.5 Uniform Plumbing Code] <br /> <br />MINIMUM COMPONENT REQUIREMENTS. Walls R-15: Floors R-21: <br />Flat Ceilings R-28: Below grade wood. concrete or masonry <br />walls R-15: Slab edge R-lO; Duct insulation R-8, R-values <br />used in this table are nominal for the insulation only and <br />not for the entire assembly. Window and skylight U-values <br />shall not exceed 0.65 (CL65). Door U-values shall not <br />exceed 0.54 (Nominal R-2). The minimum wall component for <br />Path 9 shall be an average solid log or timber wall thick- <br />ness of 2,5 inches. <br /> <br />ACCEPTABILITY, This plan review covers the addition to and} <br />or alteration of an existing structure, This review is not <br />intended to prohibit the building inspector from requesting <br />an evaluation of the acceptability of existing structural <br />members that may appear to be unsafe. Existing construction <br />not specifically detailed in the submitted plans and struc- <br />tural calculations is beyond the scope of this review. <br /> <br />97-08881 <br />ISSUED <br />09/16/1999 <br />03/14/2000 <br /> 3 <br /> <br /> <br />