My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1484296
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
97-XXXXX
>
BUILD - 1484296
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2010 11:28:36 AM
Creation date
9/2/2004 1:18:54 PM
Metadata
Fields
Template:
Permits
Permit Address
13294 DAIQUIRI LAKE DR NE
Permit City
Aurora
Permit Number
555-97-08881
Parcel Number
041W22DD05600
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />09/16/99 16:44 PERMIT NO <br />Resident. addition/alteration STATUS <br />R-3 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />97-08881 <br />ISSUED <br />09/16/1999 <br />02/14/2000 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: Left: Right: Rear: Special: <br /> <br /> 1. THIS PLAN REVIEW WAS COMPLETED BY M, JONES ON 09/16/99. <br /> 2. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 3. Approved address numbers shall be painted or affixed to the <br /> front of the building in a contrasting and highly visible <br /> color, not less than six (6) inches in height for <br /> commercial use or four (4) inches in height for residential <br /> use, The numbers shall be affixed prior to final <br /> inspection. (513) (UFC 10,301) (ORD 774) <br /> 4. A roadside marker shall be placed at the access point with <br /> address numbers in a contrasting and highly visible color, <br /> not less than five (5) inches in height for commercial use, <br /> or three (8) inches in height for residential use. <br /> 5. The INSPECTION RECORD GREEN CARD shall be posted in a <br /> visible and readily accessible location throughout <br /> construction, <br /> APPROVED CONSTRUCTION PLANS AND PLAN REVIEW COMMENTS AND <br /> CONDITIONS shall be kept on the site of the building or work <br /> at the time of inspection. <br /> 6. Work may proceed only at the direction of the inspector. <br /> To request an inspection of completed work, DIAL <br /> (503) 373-4427 (24-hour inspection line) prior to 7:00 AM to <br /> receive same day service. <br /> 7, USE INSPECTION CODES WHEN REQUESTING INSPECTIONS: <br /> 102 - FOOTINGS, stake property lines and call before pour <br /> 103 - UNDERFLOOR/POST & BEAM <br /> 104 - FRAMING, call when weather tight, chimney/fi replace <br /> installed, all backing, fire blocking, stairs, <br /> soffits in place, plumbing, electrical, mechanical <br /> complete, truss details posted, flood elevation <br /> certification submitted. <br /> 105 INSULATION. call before covered <br /> 106 DRYWALL - call before taped <br /> 107 POLE HOLES, call before pour <br /> 8. 108 FOUNDATION WALL REBAR <br /> 110 MASONRY REBAR <br /> 111 SPECIAL BRACE PANELS <br /> t12 MASONRY FIREPLACE PRE-COVER <br /> 113 SUSPENDED CEILING <br /> 114 ROOF NAILING <br /> 115 DEMOLITION INSPECTION <br /> 116 OTHER STRUCTURAL INSPECTION <br /> 199 STRUCTURAL FINAL <br /> 9. FOR FIRE SPRINKLER SYSTEMS: <br />504 FLOW TEST <br />505 FIRE ALARM TEST <br />506 TRIP TEST <br />507 FLUSHING <br />508 COMMERCIAL HOOD SUPPRESSION SYSTEM <br />509 SPRINKLER SYSTEM/OVERHEAD <br />510 SPRINKLER SYSTEM/UNDERGROUND <br />599 FIRE SPRINKLER FINAL <br />10, SAFETY GLAZING / AT DOOR. The following shall be considered <br /> specific hazardous locations for the purposes of glazing: <br /> Glazing, in an individual fixed or operable panel <br /> adjacent to a door where the nearest vertical edge is <br /> within a 24 inch arc of the door in a closed position <br /> and whose bottom edge is less than 60 inches above <br /> the floor or walking surface. Exception: Safety <br /> glazing is not required when there is an intervening <br /> wall or other permanent barrier between the door and <br /> the glazing, <br /> <br />11. SAFETY GLAZING / LARGE PANE. The following shall be con- <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.