Laserfiche WebLink
one alarm will actuate ali the alarms in the individual unit and shall provide an alarm which will <br />be audible in all sleeping areas. [Sec. 316.1] Smoke detectors shall be 110v with battery back- <br />up. [Sec. 316.2] <br /> <br />15. DUPLEX FIREWALLS. Dwelling units in two-family dwellings shall be separated from each <br />other by wall and/or floor assemblies of not less than l-hour fire. resistive rating. Fire-resistive <br />rated floor-ceiling and wall assemblies shall extend to and be tight against the exterior wall'~ and <br />wall assemblies shall extend to the underside of the roof sheathing. [Sec. 320.1] <br /> One acceptable wall construction would be a double row of staggered 2 x 4 studs @ <br />16-inch centers on 2 x 8 plates with R-15 insulation [for sound deadening] installed between 5/8- <br />inch Type X gypsum wallboard on each wall face. <br /> <br />16. FIRESTOPPING shall be provided in the following locations: <br /> 1) In concealed spaces of stud walls, including furred spaces not to exceed 10 feet <br />horizontally, and at the ceiling and floor level. <br /> 2) At all interconnections between concealed vertical and horizontal spaces such as <br />occur at soffits, drop or cove ceilings, etc. <br /> 3) In concealed spaces between stair stringers at the top and bottom of the run and wall <br />cavities in line with the stringers; <br /> 4) At openings around vents, pipes, ducts, chimneys and fireplaces at ceiling and floor <br />level, with noncombustible materials. [Sec. 602.7] <br /> <br />17. WATER HEATERS shall be anchored or strapped to the building to resist horizonta[ <br />displacement due to earthquake motion. [Sec. 510.5 Uniform Plumbing Code] <br /> <br />HEATING AND COOLING appliances located in a garage shall be protected from impact by <br />automobiles. Appliances that generate a glow, spark of flame capable of igniting gasoline <br />vapors located in a garage shall be installed with burners, burner ignition devices or heating <br />elements and switches at least 18 inches above the floor level. [Sec. 1307.3] <br /> <br />DRYER VENTS. The maximum length of a 4-inch diameter exhaust vent shall not exceed 25- <br />feet from the dryer location to wall or roof termination, and shall terminate with a full opening <br />exhaust hood. A reduction in maximum length of 2.5-feet for each 45-degree bend and 5-feet for <br />each g0 degree bend shall apply. Installations where this length limitation is exceeded shall be <br />installed in accordance with the manufacturaFs instillation instructions. [Sec. 1801.3] <br /> <br />18. ENERGY PATH #1 is based on R-21 wall insulation, R-25 underfloor insulation, R-30 <br />vaulted ceiling insulation, R-38 fiat ceiling insulation, R-21 basement wails, R-~I 5 slab floor edge <br />insulation, R-8 forced air duct insulation, 0.40 U-value window class, 0.50 U-value skylight class, <br />0,54 U-value main entry door, (with a maximum area of 24 square feet) all other exterior doors, <br />including the door between the heated dwelling and the unheated garage, 0.20 U-value. <br /> <br />planrevu\97-04990.wps <br /> <br /> <br />