Laserfiche WebLink
MARION COUNTY BUILDING INSPECTION <br />COMMUNITY DEVELOPMENT CENTER <br /> <br /> 285 Church Street NE · Room 132 · Salem, Oregon 97301-3670 <br />Office Hours: 8:00-4:30 · Phone: (503) 588-5147 · ?A-HR InepecUon Line: (503) 588-7904 <br /> <br />DATE/TIHE <br />TYPE <br />OCI~-q3PAHC:Y <br /> <br /> HANUFACTURED DgELLINO PERHIT <br /> = 03/04/96 14=47 PERHIT HO = 96-01274 <br /> = Hem Hanufactured D#elling STATUS = ISSUED <br /> = R-3 ISSUED =-03/04/1996 <br /> TO EXPIRE = ~8/31/~996 <br /> PAGE 3 <br /> manufactured dwelling ready for occupancy. 'Assigned street numbers shall be <br /> painted or affixed to the front of the dwelling in a contrasting and highly <br /> visible color, not less than four (4) inches in height. <br /> <br /> This inspection includes checking construction and code requirements for decks <br /> and steps, skirting and underfloor ventilation and access. <br /> <br />A REINSPECTION FEE OF ~60.08 shall be assessed for each inspection beyond the <br />permitted three inspections or (1) when the permit card is not Posted <br />on the job.site; (2) for. f~il~? tp pr~yide a~c~ss o~ t~e date for. which <br />the inspection is requesteo; ~ wnen tne wor~ ;or which an inspection is <br />-requested is not complete. (4) when the manufu~ctured dwelling is no~ instaileo <br />per 1996 Manufactured Dwelling Standards, or (5) when required corrections are <br />not made. No inspections will be performed until the reinspection fee has been <br />paid at our office. <br /> <br /> OTHE~ COMMENTS <br /> <br /> 1. THIS PLAN REVIEW WAS COMPLETED BY S. FREILIN~ER ON ~/1/96.. <br /> 2. Approval of'submitted plans is not an approval of omission~ <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 5. A roadside marker shall be place~ at the access point with <br /> address numbers in a contrasting and highly visible color, <br /> not less than three (3) inches in height. <br /> 4. Work may proceed only at the direction of the inspector. To <br /> ~u~st a~ inspection, of ~ompleted. work, call 588-~904 <br /> ~z;-~our iine~ prior to 7.~0 a.m. to receive same <br /> service. <br /> 5. Provide at least I square foot of underfloor ventilation <br /> fpr each 150 square feet of crawl space area. The openinqs <br /> snail be covered with a corrosion resistant wire mesh. A~ <br /> lea~t one such opening shall be provided within ~ feet of <br /> each corner of the building. (R-~11.1) <br /> 6. Provide an access crawl hole to the underfloor space. The <br /> minimum size opening required is 18 inches by 24 inches. <br /> (R-~11.2) <br /> 7. A minimum ~' x ~' landing shall be required on each side of' <br /> an ~gress door. The floor or landi~ shall not be more <br /> than one and one-half inches lower than the top of the <br /> threshold. (R-212) E~ce@tio~: The l~nding on the <br /> exterior side of an exterior ooorway snail not be more than <br /> 8 and one-half inches below the top or. the threshold. <br /> 8. Stairways shall not be less than ~ feet in clear width and <br /> the headroom shall not be less than 6 feet 8 inches. The <br /> minimum required stair tread width is 9 inches. The <br /> maximum stair rise is 8 1/4 inches. When risers are <br /> closed, all treads may have a uniform projection not to <br /> exceed I and 1/2 inches. The greatest riser height shall <br /> not exceed the smallest by more than 3/8 inch. ¢R-21~.1) <br /> 9. Handrails meeting t~e follo~ing~reguirements s~al~ b~ · <br /> provioeo on a~ least one sloe oz s~airways. The nanogrip <br /> portion of handrails shall be not ~ore than 2 5/8 inches in <br /> crops-sectional dimension, or the shape shall provide an <br /> equivalent gripping surface. Handrails shall be mounted <br /> between a minimum of ~0 inches and a maximum of J8 inches. <br /> h~y shall be continuous the full length of the stairs. <br /> nos shall be returned or shall terminate in newel posts or <br /> safety terminals. <br /> (R-21~.1)~ <br /> 10. ~rches, balconies or raised floor surfaces located more <br /> than JO in. above the floor or grade shall have guardrail <br /> not less than ~6 inches in height..R~qu~red guar~a.il shall <br /> have intermediate rails or ornamental Closures which will <br /> not allow passage of an object 6 in. or more in diameter. <br /> Horizontal spacing between the vertical members in required <br /> <br /> <br />