July 6, 1994 <br /> <br />APPLICANT: <br />SITE NUMBER: <br /> <br />LYON & ASSOGIATES <br />94-2224, <br /> <br /> Your site has been found suitable for a SAND FI~%~R ALTERNATIVE SEWAGE <br />DISPOSAL SYSTEM. The following COnStruction ~peeifications shall apply to the <br />installation of your septic system. <br /> <br /> 1. The septic tank shall hays a minimum liquid capacity of ~O0O <br /> gallons. <br /> <br /> The projected daily sewage ~low {et %his pro~ect is Calculated at <br /> 450 ~allons Der day. Based on soil conditions observed on this <br /> si~e, the disposal field will he sised at 45 lineal feet peT 250 <br /> g~0n~ of projected daily sewage flow. A minimum of 135 lineal <br /> feet Of disposal field will be required for your proposed develop- <br /> meet. The disposal trenches are ¢onstruoted two (2) feet wide and <br /> on minimum ~en (10) foe~ cen~ers and wi~h no line exceeding 125 <br /> feet in length. The trenche~ and pe~£o~ated pipe are installed <br /> level (~1") and contoured to follow the natural ground surface. <br /> <br /> 3. The disposal field shalA be SOns~ru~ted with serial distribution <br /> wfth a minimum trensh depth of 12 inches and a maKimum trench <br /> depth of ~ inches. There must De at least ~ of bs¢~flll <br /> over the top of the gravel, measured from the natural ground <br /> surface. <br /> <br /> 4. The sand ~ilter system shall be designed and operated as per OAR <br /> ~40-?1-290 through 340-71-30~- Detailed plans for the ~y~tam must <br /> be submitted prior to permit iss~an=s. A building per,it is <br /> required if a site built concrete box is used as the sand fllte~ <br /> container. A pamphlet is available in our office which details the <br /> requirements for a sand fl~ter system. <br /> <br /> capping fill is required with this system. The system shall be <br /> as indicated on the attached Capping Fill construction detail <br /> <br /> A <br />co, Strutted <br />sheet. <br /> <br /> An effluent ~ift pump m~y be ~eeessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site specific t~ ~he area tested a~d the septic system <br />must be 1neared in the i~ediate ar~a of the test pits umless otherwise autho- <br />rized by this office. A new site ~valuation may b~ required if the system is <br />proposed for a different a~ea on the property. <br /> <br />SPECIAL CONDITIONS; <br /> eenstruct the drainfields within the immediate area of the upper <br /> (northerly) two test pits. Soil conditions are marginal. Usa care not to <br /> alter the natural topsoil prior to drainfield construction. Note, the <br /> shallow del~th of the drainline trenches. The sand filter migh~ be <br /> elevated to achieve gravity ~low into the shallow trenches. A precon- <br /> struction field stak~ou~ is recommended to establish the elevations and <br /> locations of the individual drain~iel~ lines of both systems. The <br /> capping ~ill part of the installation is limited to t~e dry soil summer <br /> season. Refer tO the capping fill installation requirements for add- <br /> itional information. <br /> <br /> <br />