Laserfiche WebLink
Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure <br /> Differentials. 410 <br /> O. ASTM E1996-Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors <br /> and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. <br /> 1.3 PERFORMANCE REQUIREMENTS <br /> A. Safety Glazing Impact Performance: <br /> 1. Meets ANSI Z97.1 Class A and 16 CFR 1201 Category 11400 ft-lbs impact resistance <br /> 2. Meets ANSI Z97.1 Class B and 16 CFR 1201 Category 1150 ft-lbs impact resistance <br /> 3. Meets accelerated weathering requirements in accordance with ANSI Z97.1 <br /> B. Blast Mitigation Performance: Independent test results when tested in accordance with GSA <br /> TS01-2003, ISO 16933, ASTM F1642 and UFC 4-010-01 <br /> 1. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied with GE SCS2000 Silpruf on 114 inch (6 mm)single <br /> pane tempered glass: 2. <br /> 2. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double <br /> pane annealed glass: 2. <br /> 3. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied with Dow Corning 995 on 1/4 inch (6 mm) single pane <br /> annealed glass: 3A. <br /> 4. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied as a daylight application on 1/4 inch (6 mm) single pane <br /> annealed glass: 3B. <br /> 5. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied as a daylight application on 1/4 inch (6 mm) single pane <br /> tempered glass: 3B. <br /> 6. ISO 16933 Hazard Rating with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane tempered glass: <br /> "Hazard Rating B (EXV33(B))" . <br /> 7. ISO 16933 Hazard Rating with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane annealed glass: <br /> "Hazard Rating C (EXV33(C))". <br /> 8. ISO 16933 Hazard Rating with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with SikaSil®SG20 on 1/4 inch (6 mm) single pane tempered glass: "Hazard <br /> Rating C (EXV33(C))". <br /> 9. ISO 16933 Hazard Rating with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with an aluminum mechanical attachment on 1/4 inch (6 mm) double pane <br /> annealed glass: "Hazard Rating C (EXV33(C))". <br /> 10. ASTM F 1642 Hazard Level with a minimum blast pressure of 4 psi-28 psi-msec when <br /> applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane annealed glass: <br /> "No Hazard". <br /> 11. ASTM F 1642 Hazard Level with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane tempered glass: <br /> "No Hazard". <br /> 12. UFC 4-010-01 Protection Level with a minimum blast pressure of 4 psi-28 psi-msec <br /> when applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane annealed <br /> glass: "High Level of Protection". <br /> 13. UFC 4-010-01 Protection Level with a minimum blast pressure of 7 psi-36 psi-msec <br /> when applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane tempered <br /> glass: "High Level of Protection". <br /> C. Windborne Debris Impact and Pressure Cycling Performance: . <br /> Meets the requirements of ASTM E1996 for Large Missile Level "C" (4.5 lbs.) and <br /> 08 87 23-2 <br />