My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13000836
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
13000836
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2025 8:00:12 PM
Creation date
8/5/2025 11:51:55 AM
Metadata
Fields
Template:
Permits
Permit Address
5854 SKYLINE RD S
Permit City
Salem
Permit Number
555-21-005401-DWL
Parcel Number
083W17C 00601
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure <br /> Differentials. 410 <br /> O. ASTM E1996-Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors <br /> and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. <br /> 1.3 PERFORMANCE REQUIREMENTS <br /> A. Safety Glazing Impact Performance: <br /> 1. Meets ANSI Z97.1 Class A and 16 CFR 1201 Category 11400 ft-lbs impact resistance <br /> 2. Meets ANSI Z97.1 Class B and 16 CFR 1201 Category 1150 ft-lbs impact resistance <br /> 3. Meets accelerated weathering requirements in accordance with ANSI Z97.1 <br /> B. Blast Mitigation Performance: Independent test results when tested in accordance with GSA <br /> TS01-2003, ISO 16933, ASTM F1642 and UFC 4-010-01 <br /> 1. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied with GE SCS2000 Silpruf on 114 inch (6 mm)single <br /> pane tempered glass: 2. <br /> 2. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double <br /> pane annealed glass: 2. <br /> 3. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied with Dow Corning 995 on 1/4 inch (6 mm) single pane <br /> annealed glass: 3A. <br /> 4. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied as a daylight application on 1/4 inch (6 mm) single pane <br /> annealed glass: 3B. <br /> 5. GSA TS-01-2003, GSA Performance Condition with a minimum blast pressure of 4 <br /> psi-28 psi-msec when applied as a daylight application on 1/4 inch (6 mm) single pane <br /> tempered glass: 3B. <br /> 6. ISO 16933 Hazard Rating with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane tempered glass: <br /> "Hazard Rating B (EXV33(B))" . <br /> 7. ISO 16933 Hazard Rating with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane annealed glass: <br /> "Hazard Rating C (EXV33(C))". <br /> 8. ISO 16933 Hazard Rating with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with SikaSil®SG20 on 1/4 inch (6 mm) single pane tempered glass: "Hazard <br /> Rating C (EXV33(C))". <br /> 9. ISO 16933 Hazard Rating with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with an aluminum mechanical attachment on 1/4 inch (6 mm) double pane <br /> annealed glass: "Hazard Rating C (EXV33(C))". <br /> 10. ASTM F 1642 Hazard Level with a minimum blast pressure of 4 psi-28 psi-msec when <br /> applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane annealed glass: <br /> "No Hazard". <br /> 11. ASTM F 1642 Hazard Level with a minimum blast pressure of 7 psi-36 psi-msec when <br /> applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane tempered glass: <br /> "No Hazard". <br /> 12. UFC 4-010-01 Protection Level with a minimum blast pressure of 4 psi-28 psi-msec <br /> when applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane annealed <br /> glass: "High Level of Protection". <br /> 13. UFC 4-010-01 Protection Level with a minimum blast pressure of 7 psi-36 psi-msec <br /> when applied with GE SCS2000 Silpruf on 1/4 inch (6 mm) double pane tempered <br /> glass: "High Level of Protection". <br /> C. Windborne Debris Impact and Pressure Cycling Performance: . <br /> Meets the requirements of ASTM E1996 for Large Missile Level "C" (4.5 lbs.) and <br /> 08 87 23-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.