FIRE AND SMOKE PROTECTION FEATURES <br /> • <br /> 716.6.1 Testing under positive pressure. NFPA 257 or 716.6.8 Labeling requirements. Fire-protection-rated <br /> UL 9 shall evaluate fire-protection-rated glazing under glazing shall bear a label or other identification showing <br /> t the positive pressure. Within the first 10 minutes of a test,the the name of the manufacturer,the test standard and infor- <br /> pressure in the furnace shall be adjusted so at least two- mation required in Table 716.6 that shall be issued by an <br /> thirds of the test specimen is above the neutral pressure approved agency and shall be permanently identified on I <br /> plane,and the neutral pressure plane shall be maintained at the glazing. <br /> that height for the balance of the test. 9. <br /> 716.6.2 Nonsymmetrical glazing systems.Nonsymmetri- <br /> cal fire-protection-rated glazing systems in fire partitions, SECTION 717 <br /> fire barriers or in exterior walls with a fire separation dis- DUCTS AND AIR TRANSFER OPENINGS <br /> tance of 5 feet(1524 mm)or less pursuant to Section 705 717.1 General. The provisions of this section shall govern <br /> shall be tested with both faces exposed to the furnace, and the protection of duct penetrations and air transfer openings <br /> the assigned fire protection rating shall be the shortest in assemblies required to be protected and duct penetrations <br /> duration obtained from the two tests conducted in compli- in nonfire-resistance-rated floor assemblies. <br /> ance with NFPA 257 or UL 9. 717.1.1 Ducts that penetrate fire-resistance-rated <br /> 716.6.3 Safety glazing. Fire-protection-rated glazing assemblies without dampers. Ducts that penetrate fire- <br /> installed in fire window assemblies in areas subject to resistance-rated assemblies and are not required by this <br /> human impact in hazardous locations shall comply with section to have dampers shall comply with the require- <br /> » Chapter 24. meets of Sections 714.2 through 714.3.3.Ducts that pene- <br /> 716.6.4 Glass and glazing.Glazing in fire window assem- trate horizontal assemblies not required to be contained <br /> within a shaft and not required by this section to have <br /> blies shall be fire-protection-rated glazing installed in dampers shall comply with the requirements of Sections <br /> accordance with and complying with the size limitations 714.4 through 714.4.2.2. <br /> set forth in NFPA 80. <br /> 717.1.1,1 Ducts that penetrate nonfire-resistance- <br /> 716.6.5 Installation.Fire-protection-rated glazing shall be rated assemblies.The space around a duct penetrating <br /> in the fixed position or be automatic-closing and shall be a nonfire-resistance-rated floor assembly shall comply <br /> installed in approved frames. with Section 717.6.3. <br /> 716.6.6 Window mullions.Metal mullions that exceed a 717.2 Installation. Fire dampers, smoke dampers, combina- <br /> nominal height of 12 feet (3658 mm) shall be protected tion fire/smoke dampers and ceiling radiation dampers <br /> with materials to afford the same fire-resistance rating as located within air distribution and smoke control systems <br /> required for the wall construction in which the protective shall be installed in accordance with the requirements of this <br /> is located. section, the manufacturer's installation instructions and the <br /> 716.6.7 Interior fire window assemblies. Fire-protec- dampers' listing. <br /> tion-rated glazing used in fire window assemblies located 717.2.1 Smoke control system. Where the installation of <br /> in fire partitions andfire barriers shall be limited to use in a fire damper will interfere with the operation of a <br /> assemblies with a maximum fire-resistance rating of 1 required smoke control system in accordance with Section <br /> hour in accordance with this section. 909, approved alternative protection shall be utilized. <br /> 716.6.7.1 Where '/a hour fire protection window Where mechanical systems including ducts and dampers <br /> assemblies permitted. Fire-protection-rated glazing utilized for normal building ventilation serve as part of the <br /> requiring 45-minute opening protection in accordance smoke control system, the expected performance of these <br /> with Table 716.6 shall be limited to fire partitions systems in smoke control mode shall be addressed in the <br /> designed in accordance with Section 708 andfire barri- rational analysis required by Section 909.4. <br /> ers utilized in the applications set forth in Sections 717.2.2 Hazardous exhaust ducts.Fire dampers for haz- <br /> 707.3.6 and 707.3.8 where the fire-resistance rating ardous exhaust duct systems shall comply with the <br /> does not exceed 1 hour. Fire-resistance-rated glazing Mechanical Code. <br /> assemblies tested in accordance with ASTM E 119 or 717.3 Damper testing,ratings and actuation.Damper test- <br /> UL 263 shall not be subject to the limitations of this <br /> section. ing, ratings and actuation shall be in accordance with Sec- <br /> tions 717.3.1 through 717.3.3. <br /> 716.6.7.2 Area limitations.The total area of the glaz- 717.3.1 Damper testing. Dampers shall be listed and <br /> ing in fire-protection-rated windows assemblies shall labeled in accordance with the standards in this section. I <br /> not exceed 25 percent of the area of a common wall Fire dampers shall comply with the requirements of UL <br /> with any room. 555.Only fire dampers labeled for use in dynamic systems <br /> 716.6.7.3 Where I/3-hour fire-protection window shall be installed in heating, ventilation and air-condition- <br /> assemblies permitted. Fire-protection-rated glazing ing systems designed to operate with fans on during a fire. <br /> shall be permitted in window assemblies tested to Smoke dampers shall comply with the requirements of UL <br /> NFPA 257 or UL 9 in smoke barriers and fire parti- 555S. Combination fire/smoke dampers shall comply with <br /> teens requiring 1/4-hour opening protection in actor- the requirements of both UL 555 and UL 555S. Ceiling I <br /> dance with Table 716.6. radiation dampers shall comply with the requirements of <br /> 2019 OREGON STRUCTURAL SPECIALTY CODE 147 <br />