My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12989299
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
15-XXXXXX
>
12989299
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 8:00:14 PM
Creation date
7/31/2025 4:12:09 PM
Metadata
Fields
Template:
Permits
Permit Address
6792 SCISM RD NE
Permit City
Silverton
Permit Number
555-15-000086-DWL
Parcel Number
061W30B 01600
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRE AND SMOKE PROTECTION FEATURES <br /> (T) shall be permitted in applications that do not require 716.5.2 Other types of assemblies.Fire door assemblies <br /> compliance with temperature rise requirements.Fire-rated with other types of doors, including swinging elevator ,• y <br /> glazing assemblies marked with ratings (XXX) that doors and fire shutter assemblies,bottom and side-hinged <br /> i <br /> exceed the ratings required by this code shall be permitted. chute intake doors, and top-hinged chute discharge doors, <br /> 716.4 Alternative methods for determining fire protection shall be tested in accordance with NFPA 252 or UL IOB. <br /> ratings. The application of any of the alternative methods The pressure in the furnace shall be maintained as nearly <br /> listed in this section shall be based on the fire exposure and equal to the atmospheric pressure as possible. Once estab- <br /> acceptance criteria specified in NFPA 252,NFPA 257 or UL fished, the pressure shall be maintained during the entire <br /> • <br /> 9.The required fire resistance of an opening protective shall test period. <br /> be permitted to be established by any of the following meth- 716.5.3 Door assemblies in corridors and smoke barni- <br /> ods or procedures: ers.Fire door assemblies required to have a minimum fire <br /> 1. Designs documented in approved sources. protection rating of 20 minutes where located in corridor <br /> walls or smoke barrier walls having a fire-resistance rat- <br /> 2. Calculations performed in an approved manner. ing in accordance with Table 716.5 shall be tested in <br /> 3. Engineering analysis based on a comparison of opening accordance with NFPA 252 or UL IOC without the hose <br /> protective designs having fire protection ratings as stream test. <br /> determined by the test procedures set forth in NFPA Exceptions: <br /> 252,NFPA 257 or UL 9. <br /> 1. Viewports that require a hole not larger than 1 <br /> 4. Alternative protection methods as allowed by Section inch (25 min)in diameter through the door, have <br /> 104.11. at least a 0.25-inch-thick(6.4 mm)glass disc and <br /> 716.5 Fire door and shutter assemblies.Approved fire door the holder is of metal that will not melt out where <br /> and fire shutter assemblies shall be constructed of any mate- subject to temperatures of 1,700°F(927°C). <br /> rial or assembly of component materials that conforms to the 2. Corridor door assemblies in occupancies of <br /> test requirements of Section 716.5.1, 716.5.2 or 716.5.3 and Group 1-2 shall be in accordance with Section <br /> the fire protection rating indicated in Table 716.5. Fire door 407.3.1. <br /> frames with transom lights,sidelights or both shall be permit- <br /> ted in accordance with Section 716.5.6.Fire door assemblies 3. Unprotected openings shall be permitted for car- <br /> and shutters shall be installed in accordance with the provi- ridors in multitheater complexes where each <br /> sions of this section and NFPA 80. motion picture auditorium has at least one-half of <br /> Exceptions: its required exit or exit access doorways opening <br /> directly to the exterior or into an exit passageway. <br /> 1. Labeled protective assemblies that conform to the 4. Horizontal sliding doors in smoke barriers that <br /> requirements of this section or UL 10A,UL 14B and comply with Sections 408.3 and 408.8.4 in occu- <br /> UL 14C for tin-clad file door assemblies. pancies in Group I-3. <br /> 2. Floor fire door assemblies in accordance with Sec- 716.5.3.1 Smoke and draft control.Fire door assem- <br /> tion 711.8. blies shall also meet the requirements for a smoke and <br /> 716.5.1 Side-hinged or pivoted swinging doors. Fire draft control door assembly tested in accordance with <br /> door assemblies with side-hinged and pivoted swinging UL 1784. The air leakage rate of the door assembly <br /> doors shall be tested in accordance with NFPA 252 or UL shall not exceed 3.0 cubic feet per minute per square <br /> IOC. After 5 minutes into the NFPA 252 test, the neutral foot (0.01524 m'/s • m') of door opening at 0.10 inch <br /> pressure level in the furnace shall be established at 40 (24.9 Pa)of water for both the ambient temperature and <br /> inches(1016 mm)or less above the sill. elevated temperature tests.Louvers shall be prohibited. <br /> Installation of smoke doors shall be in accordance with <br /> NFPA 105. <br /> TABLE 716.3 <br /> MARKING FIRE-RATED GLAZING ASSEMBLIES <br /> FIRE TEST STANDARD MARKING DEFINITION OF MARKING <br /> ASTM E 119 or UL 263 W Meets wall assembly criteria. <br /> NFPA 257 or UL 9 OH Meets fire window assembly criteria including the hose stream test. <br /> D Meets fire door assembly criteria. <br /> NFPA 252 or UL IOB or UL IOC H Meets fire door assembly"Hose Stream"test. <br /> T Meets 450°F temperature rise criteria for 30 minutes <br /> XXX The time in minutes of the fire resistance or fire protection <br /> rating of the glazing assembly <br /> For SI: °C=[(°F)-321/l.8. <br /> 142 2014 OREGON STRUCTURAL SPECIALTY CODE <br />
The URL can be used to link to this page
Your browser does not support the video tag.