Laserfiche WebLink
560 8T~ ST, AUMSVILL~ <br />January 5, 1995 <br /> <br />8+ <br /> <br />This house plan uses a combination of Brace Panels (BP) and Alternate <br />Brace Panels (AEP):~q m~t th~7~.de°req~irements for lateral wall <br />bracing. Insure t~ a~ BP ~4 ~F ~ are Located as indicated <br />on the plans and c~nstrmeeed <br /> <br />In scissor trusses loose <br />~es~ than ~ inches of head.om and/or the interior ceillnq slope <br /> <br />10. <br /> <br />Any ceiling is considered vaulted when the ceiling slope is 2/12 Or <br />greater. Insulation in a flat ceiling (slope less than 2/12) shall have <br />a minimum rating of R-38. Insulation in vaulted ceilings may have a <br />minimum rating of R-30, for a. maximum of 50% of th9 total heated floor <br />spac~ area. (Oregon Energy Code) <br /> <br />THE FOLLOWING ITEMS WERE ADDED/CLARIFIED IN A pHONE CONVERSATION WITH BILL <br />~ ~/4/~. <br /> <br />12. 2 A~'S ABE BEING ADDED TO ~EE F~ONT OF THE GARAGE FOE LATERAL BRACING. <br /> (DOOR SIZE WILL BE sI~aTJ,ER) <br /> <br />13. 8' OF THE BACK WALL OF THE GARAGE IS BEING USeD AS A GYPSUM BRACE PANEL. <br /> ALL EDGES OF TEE GYPSUM PANEL S~L~LL BE BLOCKED IN T~IS 8' AREA. (ONE <br /> SIDE OF WAIJ~ ONLY) <br /> <br />Approval a~ a result of this plan review or an i~spection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code Or of other ordinances of the Jurisdiction. Reviews or inspections <br />presuming to give authority to violate Or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />DAW <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />