Permit - 1290593
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
95-XXXXX
>
Permit - 1290593
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2011 2:11:25 PM
Creation date
9/4/2003 10:09:42 AM
Metadata
Fields
Template:
Permits
Permit Address
560 8TH ST
Permit City
Aumsville
Permit Number
95-00122
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
560 8TH ST~ AUMSVILLE <br />94-04679 (60462) <br />January 5, 1995 <br />Page 1 <br /> <br />Marion <br /> OR£GOh~ <br />COMMUNITY DEVELOPMENT <br />DEPARTMENT <br /> <br /> Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the state of Oregon <br />1993 Edition One and Two Family Dwelling Specialty code. <br /> <br /> 1. A ~OPY OF THE APPROVED PLANS SHA~L B~ KEPT ON THE SITE OF THE BUILDING <br /> OR WOPA( AT THE TIME OF THE INSPECTION. (R-111.2) <br /> <br />2. The grade away from foundation walls shall fall a minimum of 6 in. <br /> within the first 10 ft., except as restricted by lot lines where the <br /> fall will be a minimum of 6 in. regardless of the horizontal distance <br /> available. (R-301.3) <br /> <br /> When reinforcement is located in the footing in the proximity of the <br /> electrical service panel, one piece of the reinforcement shall extend a <br /> minimum of 1' above the plate to act as a grounding electrode for the <br /> panel. If a piece is bent and tied, it must be tied (MINIMUM l' LAP) to <br /> a minimum 20' long section of reinforcement in the footing or wall. <br /> Contact the Electrical Inspector with questions. (N~C Article 250- <br /> <br />4. A keyway in the footing is an acceptable method and will transfer the <br /> lateral loads, oH provide a 18 inch long No. 3 dowels extending 12 <br /> inches from the footing into the wall, 4 feet on center, OR pour the <br /> footing and stemwall at one time (monolithically). All wood left <br /> permanently in contact with the foundation shall be FOUNDATION GRADE <br /> WITH ALL CUT ENDS AND/OR SIDES TREATED with an approved wood <br /> preservative. (R-310) <br /> <br /> 5. This foundation is being reviewed assuming 4 feet of unbalanced fill or <br /> less. If the actual height of fill will be more than 4 feet, then an <br /> ADDENDUM to this plan review shall be made by the permit holder, by <br /> submitting to this office revised foundation plans showing the true fill <br /> height befor~ construction commences. <br /> <br />6. Every sleeping room shall have at least one operable window approved for <br /> emergency egress or rescue. The window sill height shall not be more <br /> than 44 inches above the floor. The minimum net clear opening width <br /> dimension shall be 20 inches. The minimum net opening height shall be <br /> 24 inches. The minimum net clear opening area shall be at least 5.7 <br /> square feet. (E-210.2) <br /> <br /> 7. Individual glased areas in hazardous locations shall pass the test <br /> (CPSC 16-CFR) requirements of Section R-208.3 (safety glazing}. <br /> Hazardous locations are considered as follows: <br /> a. In doors and within 24 inches of a door. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />