Laserfiche WebLink
700 MICHAEL WAY, <br />January 26, 1995 <br /> <br />Individual glazed areas in hazardous locations shall pass the test <br />(CPSC 16-CFR) requiren~Rs ~f Se~gn ~-2~8.3 (safety glazing). <br />Hazardous locations a~'con~iderqd-as <br />d. Glazing in door~ and ~losu~es ~o~ hot tntbs, whirlpools, saunas, <br /> steam rooms, bathtubs and showers. This includes glazing IN A1TY <br /> PART OF A BUILDING WALL ENCLOSING TMESE COMPARTMENTS where the <br /> bottom edge of the glazing is less than 60" above the drain <br /> outlet. <br /> <br />This house plan uses a combination of Brace Panels (BP) and Alternate <br />Brace Panels (A~P) to met the code requirements for lateral wall <br />bracing. Insure that all B~'S and A~P'S are located as indicated <br />on the plans a~d constrnet~d as show~. <br /> <br />10. <br /> <br />ROOF OR FLOOR ROTATION is being used to meet the lateral wall <br />bracing requirements of ~h~ garage. Insure that all construction <br />reqUirements shown on the plans and o~ the enclosed 8 1/2" X 11" detail <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval cf a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to ~ive authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />DAW <br /> <br /> "APPROVED" only when this sheet is <br />attached to plans <br /> <br /> <br />