My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1289893
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
95-XXXXX
>
Permit - 1289893
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2011 8:22:44 AM
Creation date
9/4/2003 9:50:19 AM
Metadata
Fields
Template:
Permits
Permit Address
7958 SPENCER LN SE
Permit City
Aumsville
Permit Number
95-00581
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
7958 Spencer Ln. S.E., Aumsvil!e <br />March 3, 1995 <br />Page 2 <br /> <br />8 <br /> <br />10. <br /> <br />equipped with solid wood doors not less than 1 3/8 inches in thickness <br />or 20-minute fire rated, or equivalent. (R-209.2) <br /> <br />A minimum 3' X 3' landing shall be required on each side of an egress <br />door. The floor or landing shall not be more than 1-1/2" lower than <br />the top of the threshold. <br /> EXCEPTION: The landing on the exterior side of an exterior <br /> doorway shall not be more than 8-1/2" below the top of the thresh- <br /> old. <br /> <br />Roof trusses are required to be designed by an Oregon registered <br />Engineer or Architect. For trusses manufactured by an approved fabrica- <br />tion plant, have the design and layout drawings available at the <br />construction site for the framing inspection. All job site cutting or <br />modification of the roof trusses shall be clearly shown in the engine- <br />er's design calculations and drawings_ <br /> <br />It is assumed that this building will be neither heated or cooled. If <br />this structure is to be heated or cooled, it will be required to meet <br />the applicable Energy Code requirements. <br /> <br />If a ceiling is installed in this structure, provide screened attic <br />vents with a net free area of 1/150 of the attic area (or 1/300 if half <br />is along eaves and the other half in the uDDer portion). A readily <br />accessible attic access shall be provided to any attic area having a <br />clear height of over 30 inches. A framed opening not less than 22 in. <br />by 30 in. is required. (R-708) (R-707) <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />mm <br /> <br />"APPROVED" only when this sheet is at- <br />tached to plans <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.