Laserfiche WebLink
December 6, 1994 <br /> <br />APPLICANT~ <br />SITE NUMBER~ <br /> <br />STANDARD SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />JOHN M. GROSS <br />94-4133, LOT 6, BLOCK 4, PATTON ADDITION <br /> <br /> Your site has been found suitable for a STANDARD ON-SITE SEWAGE DISPOSAL <br />SXSTEM. The following construction specifications shall apply to the installa- <br />tion of your septic system. <br /> <br />The septic tank shall have a minimum liquid capacity of 1000 <br />gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />450 qal. lons per day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 75 lineal feet per 15q <br />gallons of projected daily sewage flow. A minimum Of 225 lineal <br />feet of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2} feet wide and <br />on minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with serial distribution <br />with a minimum trench depth of 24 inches and a maximum trench <br />depth of .~6 inches. There must be at least 12 inches of backfill <br />over the top of the gravel, measured from the natural ground <br />surface. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the i~mediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS: <br /> The drainfields must be installed as far upslope as possible to allow <br /> space for a complete replacement system. A pre-permit field stakeout is <br /> required to establish the elevations and locations of the individual <br /> lines of both drainfields. Alternative seepage trenches Or a sand filter <br /> system can be considered for the replacement system if space is not <br /> available to site a complete standard replacement drainfield. Refe~ to <br /> the stakeout procedure and the setback list for details to complete the <br /> stakeout. Use care not to alter the natural topsoil prior to d~ainfield <br /> installation. Dry soil summer season construction is recommended due to <br /> limitations of the steep slope and wooded hillside. <br /> <br />__TH~S IS NOT A PEP24IT TO INSTALL THE SEPTIC SYSTEM. DO NOT INSTALL THB SYSTEM <br />UNTIL A VALID PERMIT HAS BEEN ISSUED BY THIS OFFICE. <br /> <br /> <br />