9493 Porter Rd. SE, Aumsville <br />July 11, 1994 <br />Page 2 <br /> <br />and other construction shall not interfere with the accessibility to or <br />within under-floor areas. <br /> <br />Underfloor areas shall be ventilated by an approved mechanical means or <br />by openings in the exterior foundation walls. Such openings shall have <br />a net area of not less than 1 square foot for each 150 square feet of <br />underfloor area. Openings shall be located as close to corners as <br />practicable and shall provide cross ventilation on at least two <br />approximately opposite sides. (2516(c)6) <br /> <br />This site, building and facilities are required to be accessible to and <br />useable by the physically handicapped. Details and dimensions not shown <br />shall comply with Public Law 101-336, the Americans with Disabilities <br />Act, Part III; Department of Justice Regulations of Friday, July 26, <br />1991; 28 C.P.R., Part 36, including Americans with Disabilities Act <br />Accessibi%ity Guidelines (ADAAG) and Public Law 100-430, the Fair <br />Housing Act and the regulations adopted thereunder and the requirements <br />of Chapter 31. (3101} <br /> <br />Accessible parking facilities shall be provided, constructed, marked, <br />signed, and maintained as required by Section 3104. See Table No. 31-A <br />for the number of spaces required. <br /> <br />Table NO. 31-A <br /> <br />MINIMUM REQUIRED <br />NUMBER OF TOTAL ACCESSIBLE SPACE1 <br />1-25 1 <br />26-50 2 <br />51-75 3 <br />76-100 4 <br />101-150 5 <br />151-200 6 <br />201-300 7 <br />301-400 8 <br />401-500 9 <br />501-999 2% of total s~9~es <br />Over 1',000 20 spaces plus 1 for every <br /> 100 spaces, or fraction <br /> thereof over 1,000. <br /> <br />by an access aisle 96 inches wide minimum and shall be designated van <br /> <br />All such spaces may be grouped on one level of a parking structure. <br /> <br /> <br />