My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1287288
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1287288
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2011 10:25:53 AM
Creation date
9/4/2003 8:45:51 AM
Metadata
Fields
Template:
Permits
Permit Address
945 OLNEY ST
Permit City
Aumsville
Permit Number
94-01358
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Plan Review M25-94-2227C <br />Blazer Industries <br /> <br />No modification to this structure shall be commenced without the approval of the design engineer, the <br />local building official and the l:'refabricated Structures Section of the Building Codes Division. <br /> <br />Foundation systems, marriage connections of multiple component units, site work done outside of the <br />confines of the stracture (plumbing, electrical, gas piping, and utility connections) are the <br />responsibility of the local building deparunent having site jurisdiction. <br /> <br />REFER. TO APPROVED PLANS FOR NOTES PF.~ TO IltlS PARTICULAR PROJECT. <br /> <br />FOR ELECTRICAL INSPECTIONS CALL (503)373-1239 or 373-1315. <br /> <br />I/~SPECTIONS REQI. JIREn: COVER: .X FINAL: X <br /> *l-hr...naffing (~ 1-hr. occupancy wall and 1-hr, .damper. <br /> *Split limits to 10-5/8" <br /> <br />Submitted plans are acceptable subject to the following: <br /> <br />A one-hour rated damper shall be provided @ duct penetration through one-hour occupancy <br />separation per OSSC 4306(j)1. <br /> <br />Unless otherwise specified in the hWAC installation standards, not less than 30 inches of <br />clearance shall be provided in front of appliance for ~rvlceable work space in accordance with <br />OSMSC 505. <br /> <br />In accordance with Plans Sheet 2a, Section B, double trusses are proposed as framing members <br />for 1-hour occupancy separation wall above ceiling. In accordance with one-hour assembly <br />utilized, provide vertical framing at 24" o.c~ max. <br /> <br />l~ndwall shear design proposed at endwall with door and 2 ea. windows indicates fastening <br />siding with 6d at 2" o.c. In accordance with OSSC Table 25~K-I, Footnote 2, 3-inch nominal <br />framing shall be provided and nails at 2" o.c. shall be staggered in shearpanel locations. <br /> <br />Those portions of supply plenum and ducting above the insulation envelope in the ceillng <br />within aa unconditioned space shall be provided with minimum R~$ duct insulation per <br />OSSC Table 53-P, Path 1. <br /> <br /> <br />