740 DELMAR DR, AUMSVILLE <br />94-1276 (9053911) <br />April 20, 1994 <br />Page i <br /> <br />Marion Cou, nty <br /> OR~CON <br />COMMUNITY DEVELOPMENT <br />O~PARTM£NT <br /> <br />Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1993 Edition One and Two Family Dwelling Specialty code. <br /> <br />A copy of approved plans when required by the building official shall be <br />kept on the site of the building or work at the time of inspection. <br />(R-111.2) <br /> <br />10. <br /> <br />22. <br /> <br />23. <br /> <br />38. <br /> <br />42. <br /> <br />Approved numbers or addresses shall be placed on all buildings in such a <br />position as to be plainly visible and legible from the street or road <br />fronting the property. (UFO 10.208) <br /> <br />The grade away from foundation walls shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines where the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />Basement walls, foundation walls, and other vertical concrete exposed to <br />the weather shall have a minimum specified compressive strength of <br />3000 psi. Porches, carport slabs, garage floor slabs and steps exposed <br />to the weather shall have a minimum specified compressive strength of <br />3500 psi. Table No. (R-302.2) <br /> <br />Provide at least 1 square foot of underfloor ventilation for each 150 <br />square feet of crawl space area. The openings shall be covered with a <br />corrosion resistant wire mesh. At least one such opening shall be <br />provided within 3 feet of each corner of the building. (R-311.1) <br /> <br />Provide an access crawl hole to the underfloor space. The minimum size <br />opening required is 18 inches by 24 inches. (R-311.2) <br /> <br />The garage shall be completely separated from the residence and its <br />attic area by means of 1/2-inch gypsum board or equivalent applied to <br />the garage side. The door between the garage and residence shall be <br />equipped with solid wood doors not less than 1 3/8 inches in thickness <br />Or 20-minute fire rated, or equivalent. (R-209.2) <br /> <br />Heating and cooling appliances located in a garage shall be protected <br />from impact by automobiles. Appliances that generate a glow, spark of <br />flame capable of igniting gasoline vapors located in a garage shall be <br />installed with burners, burner ignition devices or heating elements and <br />switches at least 18 inches above the floor level. (M-1006.3) <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. In dwelling units with eplit <br />levels, a smoke detector need be installed only on the upper level, <br />provided the lower level is less than one full story below the upper <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />