Laserfiche WebLink
485 OLN~Y ~, AUM~VILLR <br />April 19, 1994 <br />Page 2 <br /> <br />54. <br /> <br />Provide screened attic vents with a net free area of 1/150 of the attic <br />area (or 1/300 if half is along eaves and the other half in the upper <br />portion). (R-707) <br /> <br />56. <br /> <br />A readily accessible attic access shall be provided to any attic area <br />having a clear height of over 30 inches. A framed opening not less than <br />22 in. by 30 in. is required. (R-708) <br /> <br />Approval as a r~sult of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />FP <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />