Laserfiche WebLink
580 8TH ST, AUMSWILLE <br />May 5, 1994 <br />Page 2 <br /> <br />CONDITION 1 TYPE OF ERAcE AMOUNT OF BRACING 2 3 <br />One Story. 1-by 4-inch let-in Located at each end and <br />Top of two or three bracing or structural at least every 25 feet <br />story.. ........... sheathing, of wall length. <br />First story of two Structural sheathing. 25 percent of wall <br />story, length to be sheathed. <br />Second story of three <br />First story of three Structural sheathing. 40 percent of wall <br />story, length to be sheathed. <br /> <br />1 Foundations wall panels braced same as story above. <br />2 Where structural sheathing is used, each braced panel must be at least 48 <br /> inches in width. <br />3 Structural sheathing and let-in bracing shall be located at each end or as <br /> near thereto as possible. <br /> <br />Approval as a result of this plan review or an inspection shall net be <br />construed to be an approval of a violation of the provisions of the dwelling <br />Code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />PP <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />