My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1286922
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1286922
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2011 12:53:23 PM
Creation date
9/4/2003 8:38:36 AM
Metadata
Fields
Template:
Permits
Permit Address
11425 EHLEN RD NE
Permit City
Aurora
Permit Number
94-01440
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Bldg #2: <br />May 10, <br />Page 2 <br /> <br />Hay Storage: 13,480 sq.ft. <br />1994 <br /> <br />Every building shall have sanitary fixtures installed as required by <br />Section 510 and Table No. 5-E. Where sanitary fixtures are located in <br />an adjacent building on the came property, toilet facilities may be <br />omitted in the new building. (510(a)) <br /> <br />The Mesco Metal Building Corporation plans cubmitted do not show enough <br />information for a structural plan review of the pre-engineered metal <br />building. Submit (2) structural plans that show frame dimencions <br />(member depth, plate width and thickness, etc.) and connection details. <br />Include endwall details and X-bracing. Submit (1) set calculations Of <br />structural design calculations for the building. <br />(W = 63.5'; L = 210.3'; H = 28.6'; BAY = 25'/30') A certification <br />letter submitted indicates design loads (SNOW = 25 PSF; WIND = 90 MP~ <br />Exp. C) that are acceptable. <br /> <br />The design of steel used structurally in buildings shall conform to the <br />requirements specified in U.B.C Chapter 27 and U.B.C. Standard NO. 27-1. <br />Where the design uses ASTM A-36 steel with yield strength (Fy) greater <br />than 36 ksi, as an alternate material, the metal building designer shall <br />submit mill certifications showing the yield strength from tests on the <br />steel incorporated into the building exceed the decign Fy by 10%. (105) <br /> <br />A water supply sufficient to control a potential fire is required. See <br />Appendix III-A of the Uniform Fire code. Contact the local fire <br />department and Deputy State Fire Marshal for requirements. The chief <br />shall establish the minimum residual pressure and flow duration when <br />determining fire flow. (U.F.C. 10.401) <br /> <br />Portable fire extinguishers shall be provided and installed ac required <br />by applicable standards and as directed by the authority having <br />jurisdiction. (U.F.C. 10.505; U.F.C. Std. NO. 10-1) <br /> <br />Approval of submitted plans is not an approval of emissions or oversights by <br />this office or of noncompliance with any applicable regulations of local <br />government. <br /> <br />This project may be subject to the architectural standards of the Americans <br />with Disabilities Act of 1990 (ADA). Issuance of a building permit does not <br />certify compliance with this Federal Statute. copies of the guidelines and <br />information concerning the ADA may be obtained from the Architectural and <br />Transportation Barriers Compliance Board, 1-202-653-7834 (voice/TDD) or <br />1-800 USA-ABLE. Failure to comply with the ADA may result is Federal Fines <br />and penaltiec. <br /> <br />Local Fire Districtc may have additional requirements that affect this <br />project. You are advised to contact the Fire District before you proceed. <br /> <br />If you have any questions, please contact me at 588-5147. <br /> <br /> O P.E. <br />PLAN CHECK ENGINEER <br /> <br />DONALD WC~DDLEY <br />~U~LDING OFFICIAL <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.