365 DELMAR, AUMSVILLE <br />94-01839 (54876) <br />June l, 1994 <br />Page 2 <br /> <br />9 <br /> <br />10. <br /> <br />Wood framed walls a minimum of two feet and less than four feet wide at <br />garage door openings shall be provided with approved hold-down anchors <br />at each end of each wall segment. The hold-downs shall connect the wall <br />studding to the ¢o~crete foundataion. <br /> <br />A readily accessible attic access shall be provided to any attic area <br />having a clear height of over 30 inches. A framed opening not less than <br />22 in. by 30 in. is required. (R-708) <br /> <br />Energy Path #1 is based on R-21 wall insulation, R-25 underfloor <br />insulatiion, R-30 vaulted ceiling insulation, R-38 flat ceiling <br />insulation, R-21 basement walls, R-15 slab floor edge insulation, R-$ <br />forced air duct insulation, 0.40 U-value window class, 0.50 U-value <br />skylight claes, 0.54 U-value main entry door with a maximum of 24 square <br />feet and 0.20 U-value doors, other than the main entry (including the <br />door between the heated dwelling and the unheated garage). <br /> <br />12. GARAG~ DOOR HEADER $~ALL ~E A MINIMUM OF 4" x 10" 2orB. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />DAW <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />