My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1286878
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1286878
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2011 12:39:23 PM
Creation date
9/4/2003 8:37:30 AM
Metadata
Fields
Template:
Permits
Permit Address
385 DEL MAR DR
Permit City
Aumsville
Permit Number
94-01839
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
~DELMAR, AUMSVILL~ <br />94-01839 (54876) <br />June 1, 1994 <br />Page 1 <br /> <br />Marion County <br /> OREGON <br />COMMUNITY DEV£LOPMENT <br />DE ?^R, TMIENT <br /> <br /> Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1993 Edition One and Two Family Dwelling Specialty Code. <br /> <br />A copy of approved plans shall be kept on the site of the building or <br />work at the time of inspection. (R-ii1.2) <br /> <br />The grade away from foundation walls shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines where the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />Openings between the garage and residence shall be equipped with either <br />solid wood doors not less than 1 3/8 inches in thickness or 20-minute <br />fire rated doors, or equivalent. (R-209.1) <br /> <br />Appliances that generate a glow, spark or flame capable of igniting <br />gasoline vapors and located in a garage shall be installed with burners, <br />burner ignition devices or heating elements and switches at least 15 <br />inches above the floor level (M-1006.3) <br /> <br />In new construction, required smoke detectors shall receive their <br />primary power from the building wiring and when primary power is <br />interrupted, shall receive power from a battery. (R-215.2) <br /> <br />Bathrooms shall be provided with artificial light and an approved <br />mechanical ventilation system capable of producing a change of air every <br />12 minutes or a window Of not less than 3 sq. ft., one-half of which <br />must be openable. (R-203.3) <br /> <br />Individual glazed areas in hazardous locations shall pass the test <br />(CPSC 16-CFR) requirements of Section R-208.3 (safety glazing). <br />~azardous locations are considered as follows: <br /> <br />Zn doors and within 24 inches of a door. <br />Fixed and sliding panels of sliding-type doors (patio type). <br />Glazing in storm doors. <br />Glazing in shower and bathtub doors and enclosures. <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.