Laserfiche WebLink
11952 steinkamp Road SE <br />Permit ~ 55084 <br />Control # 94-1939 <br />June 8, 1994 <br />Page 1 <br /> <br />Marion County <br /> OREGON <br />COMMUNITY D£VIkOPMI~NT <br />DI~PARTMENT <br /> <br /> Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the state of Oregon <br />1993 Edition One and Two Family Dwelling Specialty Code. <br /> <br />A copy of approved plans shall be kept on the site of the building or <br />work at the time of inspection. (R-ii1.2) <br /> <br />Approved numbers or addresses shall be placed on all buildings in such a <br />position as to be plainly visible and legible from the street or road <br />fronting the property. (UFC 10.208) <br /> <br />The grade away from foundation walls shall fall a minimum of 6 in. <br />within the first 10 ft., except as restricted by lot lines where the <br />fall will be a minimum of 6 in. regardless of the horizontal distance <br />available. (R-301.3) <br /> <br />When the footing and stemwall are poured in two separate pours, a keyway <br />in the footing is an acceptable method of transferring lateral loads <br />(seismic or wind) from the stemwall into the footing, or as an <br />alternate, provide 18 inch long NO. 3 dowels, extending 12 inches into <br />the wall from the footing, spaced at 4 feet on center. <br /> <br />Porches, balconies or raised floor surfaces located more than 30 in. <br />above the floor or grade shall have guardrail not less than 36 inches in <br />height. Required guardrail shall have intermediate rails or ornamental <br />closures which will not allow passage of an object 6 in. or more in <br />diameter. Horizontal spacing between the vertical members in required <br />guardrails shall be a maximum of 4 inches at the nearest point between <br />the members. (R-214.2) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. In dwelling units with split <br />levels, a smoke detector need be installed only on the upper level, <br />provided the lower level is less than one full story below the upper <br />level, except that if there is a door between levels then a detector is <br />required on each level. All detectors shall be interconnected such that <br />the actuation of one alarm will actuate all the alarms in the individual <br />unit and shall provide an alarm which will be audible in all sleeping <br />areas. (R-215.1) <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />